PG-FP5-EA Renesas Electronics America, PG-FP5-EA Datasheet - Page 212

no-image

PG-FP5-EA

Manufacturer Part Number
PG-FP5-EA
Description
PROGRAMMER FLASH MEMORY UNIV
Manufacturer
Renesas Electronics America
Datasheets

Specifications of PG-FP5-EA

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PG-FP5
A.4 Error Messages Displayed in FP5 Message Display
R20UT0008EJ0400 Rev. 4.00
Jul 15, 2010
001
002
005
006
008
011
012
013
014
015
016
020
021
022
023
024
025
026
027
030
032
040
041
042
043
No.
Invalid PRM data
Not connected
Not supported!
Command aborted! Command aborted
Parameter Error!
Read. Sig failed
Check connection
Addr. Range err
RDY detect. fail
Freq. set failed
Baudrt. set fail
Inv. Sig. ID
Inv. Sig. Code
Inv. Sig. func.
Inv. Sig. addr.
Inv. device name
Inv. Signature
Inv Dev/Firm ver
Unkn. Signature
Prewrite Timeout
Prewrite failed
Erase Timeout
Erase failure
Ers time exceed
Ers Timeset err
Message
Invalid PRM data
No device connected to FP5
PR5 file Error
Device signature reading failed
Connection check
Address range error
Device does not send RDY signal. Wrong connection between device and FP5 or bad socket
Setting the Oscillator frequency
failed.
Setting the communication baud
rate failed.
Invalid signature ID
Invalid signature code
Invalid signature function
Invalid signature address
Invalid device name
Invalid signature
Invalid device firmware version
Unknown Signature
Prewrite timed out
Prewrite retry error
Erase timed out
Erase failed
Erase timed out
Erase time setting error
Error Condition
The parameter file may include invalid data, or the file may be
defective. Re-set the file using the parameter file downloaded
from http://www2.renesas.com/micro/en/ods/
Issue a ‘con’ command before the command causing this
error.
The command issued is not supported on the device and thus
cannot be used.
The [Read] command has been canceled.
The parameter file may be damaged.
Check if the correct device is selected.
The FP5 cannot establish connection to the target device.
The cause may be a wrong connection between the device
and the FP5, bad socket contacts or the oscillator not
operating.
The address given in the command exceeds the device’s
address range.
contacts.
Check if the oscillator frequency is allowed. If yes, contact
Renesas Electronics support desk.
Unsupported baud rate specified. Please consult the device
manual.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Check if the correct device is selected.
Check, if the correct PRM file is used.
A communication problem occurred between the FP5 and
target device. Try the operation again.
The device may be damaged.
A communication problem occurred between the FP5 and
target device. Try the operation again.
The device may be damaged.
The device may be damaged.
The PR5 file may contain invalid data. Contact Renesas
Electronics.
Possible Workaround
APPENDIX A MESSAGES
Page 212 of 240
(1/3)