P2CF-08-E Omron, P2CF-08-E Datasheet - Page 18

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
■ Operating Procedures (Timer Function)
Settings for Basic Functions
Note: All the pins are factory-set to OFF.
Note 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled.
1
2
3
4
5
6
7
8
Settings for basic functions can be performed with just the DIP switch.
Easy Confirmation of Switch Settings Using Indicators
The ON/OFF status of the DIP switch pins can be
confirmed using the front display. For details, refer to page 31.
After making DIP switch settings for basic functions, detailed settings (see note) can be added using the operation keys.
For details, refer to page 19.
Note: Output time, NPN/PNP input mode, display color, key protect level.
Detailed Settings
2. Changes to DIP switch settings are enabled when the power is turned ON. (Perform DIP switch settings while the power is OFF.)
3. There is no DIP switch on the H5CX-L8@. For details on the setting methods, refer to page 19.
4. When using time ranges or output modes that cannot be set with the DIP switch, all of the settings have to be made using the operation
keys. For details on the setting methods, refer to page 19.
DIP switch set-
tings enable/
disable
Time range
Output mode
Timer mode
Input signal
width
Item
Disabled
Refer to the table on the right.
Refer to the table on the right.
Elapsed time
(UP)
20 ms
OFF
OFF
ON
Enabled
Remaining time
(DOWN)
1 ms
1
ON
Be sure to set pin 1 to ON when using the DIP switch.
2
3
4
5
6
7
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
Pin 2
Pin 5
ON
OFF
OFF
ON
ON
OFF
OFF
ON
Pin 3
OFF
OFF
ON
ON
Pin 6
ON
OFF
OFF
OFF
OFF
ON
ON
ON
Pin 4
(I): power reset operation)
A-2 mode: (power ON de-
lay (I): power reset opera-
tion)
E mode (interval: power
reset operation)
F mode (accumulative:
power hold operation)
A mode (signal ON delay
0.001 s to 9.999 s
0.01 s to 99.99 s
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to 99 min
59 s
0.1 min to
999.9 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
Output mode
Time range
H5CX-A/-L
18