P2CF-08-E Omron, P2CF-08-E Datasheet - Page 44

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Operating Procedures
■ Setting Set Values
Set values can be set either as offset values (forecast value setting)
or absolute values. Set values are factory-set to forecast value set-
ting.
1. Move to Setting Method Selection Mode by turning ON the power
2. Select forecast value setting (
3. When the power is turned ON again, the Timer will start with the
Note 1: In Setting Method Selection Mode, outputs are OFF and the
Setting Method
Selection Mode
while pressing both the
(
selected setting method.
Run Mode
2: When the setting method is changed, the set values and
) using the
timer is stopped.
present value are reset to 0, and outputs are OFF.
Turn ON the power again.
Turn ON the power while
pressing the
4 Key.
Keys.
Key and
Key and
(Forecast value setting) (Absolute value setting)
) or absolute value setting
Change the setting method
using
4 Key at the same time.
Keys 1 to 6.
Timing stopped
Timing possible
Forecast Value Setting
• OUT1 (forecast output) turns ON when the present value reaches
• OUT2 (control output) turns ON when the present value reaches
• If the forecast set value ≥ set value, OUT1 (forecast output) will turn
Absolute Value Setting
• OUT1 (control output 1) turns ON when the present value reaches
• OUT2 (control output 2) turns ON when the present value reaches
Example: F-1 Mode
Example: F-1 Mode
Control output 2 (OUT 2)
Control output 1 (OUT1)
the forecast value.
The forecast value = set value − forecast set value
The forecast set value is used to set the deviation for the set value.
the set value.
ON as soon as timing starts.
set value 1.
set value 2.
Forecast
set value
Forecast output (OUT1)
Control output (OUT 2)
Set value 1
Set value 2
Forecast value
Set value
0
0
Present value
Present value