P2CF-08-E Omron, P2CF-08-E Datasheet - Page 45

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
■ DIP Switch Settings
All functions are set using the DIP switch.
Note 1: All the pins are factory-set to OFF.
■ Operation in Run Mode
Set each digit for the set value using the corresponding
Forecast Value Setting
Absolute Value Setting
1
2
3
4
5
6
7
8
2: DIP switch settings are effective when the power is turned
3: The characters displayed in reverse video are the default set-
Time range
Output mode
Input signal width
NPN/PNP input
mode
Reset Key protec-
tion
Up Key protection
Mode Key protec-
tion
ON again. (Set the DIP switch before installation and power-
up.)
tings.
Item
Present value
Set value
Set value 1
Set value 2
Present value
Present value
Forecast set value
Present value
Refer to the table on the right.
F-1 mode
20 ms
NPN
Disabled
Disabled
Disabled
OFF
Each time the
pressed, the sub-display
will switch between set
value 1 (“SET 1” is lit) and
set value 2 (“SET 2” is lit).
Each time the
pressed, the sub-display will
switch between the set
value (“SET” is lit) and the
forecast set value (“1” is lit).
A mode
1 ms
PNP
Enabled
Enabled
Enabled
ON
Key is
Key is
Keys.
OFF
ON
OFF
ON
Pin 1
OFF
OFF
ON
ON
Pin 2
0.1 h to 99999.9 h
0.01 s to 9999.99 s
0 h 00 min 01 s to 99 h 59 min 59 s
0.1 min to 99999.9 min
OFF
ON
(Default setting)
Time range
1
2
3
4
5
H5CX-B
6
7
8
45