EM250-BBRD-R Ember, EM250-BBRD-R Datasheet - Page 54

EM250 BREAKOUT BOARD

EM250-BBRD-R

Manufacturer Part Number
EM250-BBRD-R
Description
EM250 BREAKOUT BOARD
Manufacturer
Ember
Type
Transceiver, 802.15.4r
Datasheet

Specifications of EM250-BBRD-R

Frequency
2.4GHz
For Use With/related Products
EM250
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
636-1024
EM250
SC1_DMASTAT [0x4496]
SC1_RXCNTA [0x4490]
120-0082-000S
SC1_RXFRMB
SC1_RXFRMA
SC1_RXPARB
SC1_RXPARA
SC_RXOVFB
SC_RXOVFA
SC_TXACTB
SC_TXACTA
SC_RXACTB
SC_RXACTA
SC1_RXCNTA
SC1_RXPARB
0-R
0-R
0-R
0-R
15
15
0
0
7
7
SC1_RXPARA
0-R
0-R
0-R
0-R
14
14
0
6
0
6
[9]
[8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
[12:0]
SC_RXOVFB
This bit is set when DMA receive buffer B was passed a frame error from the lower hardware
FIFO. This bit is autocleared the next time buffer B is loaded or when the receive DMA is reset.
This bit is set when DMA receive buffer A was passed a frame error from the lower hardware
FIFO. This bit is autocleared the next time buffer A is loaded or when the receive DMA is reset.
This bit is set when DMA receive buffer B was passed a parity error from the lower hardware
FIFO. This bit is autocleared the next time buffer B is loaded or when the receive DMA is reset.
This bit is set when DMA receive buffer A was passed a parity error from the lower hardware
FIFO. This bit is autocleared the next time buffer A is loaded or when the receive DMA is reset.
This bit is set when DMA receive buffer B was passed an overrun error from the lower hardware
FIFO. Neither receive buffers were capable of accepting any more bytes (unloaded), and the
FIFO filled up. Buffer B was the next buffer to load, and when it drained the FIFO, the overrun
error was passed up to the DMA and flagged with this bit. This bit is autocleared the next time
buffer B is loaded or when the receive DMA is reset.
This bit is set when DMA receive buffer A was passed an overrun error from the lower hardware
FIFO. Neither receive buffers were capable of accepting any more bytes (unloaded), and the
FIFO filled up. Buffer A was the next buffer to load, and when it drained the FIFO the overrun
error was passed up to the DMA and flagged with this bit. This bit is autocleared the next time
buffer A is loaded or when the receive DMA is reset.
This bit is set when DMA transmit buffer B is currently active.
This bit is set when DMA transmit buffer A is currently active.
This bit is set when DMA receive buffer B is currently active.
This bit is set when DMA receive buffer A is currently active.
A byte offset (from 0) which points to the location in DMA receive buffer A where the next
byte will be written. When the buffer fills and subsequently unloads, this register wraps
around and holds the value zero (pointing back to the first location in the buffer).
0-R
0-R
0-R
0-R
13
13
0
5
0
5
SC_RXOVFA
0-R
0-R
0-R
0-R
12
12
0
4
4
SC1_RXCNTA
Page 54
SC_TXACTB
0-R
0-R
0-R
0-R
11
11
0
3
3
SC1_RXCNTA
SC_TXACTA
0-R
0-R
0-R
0-R
10
10
0
2
2
SC1_RXFRMB
SC_RXACTB
0-R
0-R
0-R
0-R
9
1
9
1
SC1_RXFRMA
SC_RXACTA
0-R
0-R
0-R
0-R
8
0
8
0

Related parts for EM250-BBRD-R