Specifications of PN5120A0HN/C2,551

Rf Type
Read / Write
Frequency
13.56MHz
Features
ISO14443-A, ISO14443-B
Package / Case
40-VFQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PN5120A0HN/C2,551
Manufacturer:
COPAL
Quantity:
12
NXP Semiconductors
PN512
Product data sheet
COMPANY PUBLIC
9.2.4.6 TestBusReg
9.2.4.7 AutoTestReg
9.2.4.8 VersionReg
Shows the status of the internal testbus.
Table 120. TestBusReg register (address 35h); reset value: XXh, XXXXXXXXb
Table 121. Description of TestBusReg bits
Controls the digital selftest.
Table 122. AutoTestReg register (address 36h); reset value: 40h, 01000000b
Table 123. Description of bits
Shows the version.
Bit
7 to 0
Bit
7
6
5
4
3 to 0
Access Rights
Access Rights
Symbol
TestBus
Symbol
-
AmpRcv
-
EOFSOFAdjust If set to logic 0 and the EOFSOFwidth is set to 1 will result in the
SelfTest
All information provided in this document is subject to legal disclaimers.
RFT
7
7
0
r
Rev. 3.6 — 10 March 2011
Description
Shows the status of the internal testbus. The testbus is selected by the
register TestSel2Reg. See
AmpRcv
Description
Reserved for production tests.
If set to logic 1, the internal signal processing in the receiver chain is
performed non-linear. This increases the operating distance in
communication modes at 106 kbit.
Note: Due to the non linearity the effect of the bits MinLevel and
CollLevel in the register RxThreshholdReg are as well non linear.
Reserved for future use.
Maximum length of SOF and EOF according to ISO/IEC14443B
If set to logic 0 and the EOFSOFwidth is set to 0 will result in the
Minimum length of SOF and EOF according to ISO/IEC14443B
If this bit is set to 1 and the EOFSOFwidth bit is logic 1 will result in
SOF low = (11 etu − 8 cycles)/fc
SOF high = (2 etu + 8 cycles)/fc
EOF low = (11 etu − 8 cycles)/fc
Enables the digital self test. The selftest can be started by the selftest
command in the command register. The selftest is enabled by 1001.
Note: For default operation the selftest has to be disabled by 0000.
r/w
6
r
6
111336
RFU
5
r
5
0
EOFSO
FAdjust
RFU
4
r
4
TestBus
Section 20
r/w
3
r
3
“Testsignals”.
r/w
2
r
2
Transmission module
SelfTest
© NXP B.V. 2011. All rights reserved.
r/w
1
1
r
PN512
60 of 125
r/w
0
0
r