7 Communication
2.
*Footnote 1: You could select number system of the Hexadecimal, the Decimal or the
ASCII code system for display after clicking “View” > “Monitoring Data Format(N)”. In
ladder diagram monitor mode, there will be a letter represented in the front of number to
distinguish the number system. For signed decimal system, it is K, such as K1234, and H
for hexadecimal system, such as HABCD. If it is ASCII code, the figure has to be the ASCII
code for display, otherwise, it will be “ * ”.
7-12
After starting monitor, the green portion displayed in the window is an indication that
the contact is at the continuity status or the output coil is ON. On the contrary, if the
green color does not display on the contact or the output coil, it means that this portion
is currently OFF. Moreover, the current value (*Footnote 1) of the register will be
shown on the upper part of the register (T, C, D) as shown below.