8 SFC Mode
8-8
Step 4: After the editing is completed, close the internal ladder diagram mode, and the
Step 5: When you want to modify the inner ladder diagram of the diagram LAD-0, move
Step 6: Next, plan to edit the initial step point diagram. Move the editing block to the
No transition condition diagram for step point is needed between the ladder diagram
mode and the initial step point diagram
program that was just edited will be saved in the ladder diagram LAD-0. At this
time, if you double click the mouse to activate the “Inner Ladder Mode”, then
you can see the previous edited inner ladder diagram or inner instruction
already existed in the ladder diagram LAD-0.
the editing block to where the diagram LAD-0 is, and right click you mouse to
choose the “Inner Ladder Mode” from the pop-up menu (Refer to Step 2 and
Step 3).
next row and press the function key [F2], or click
same time, the SFC editing window will request you to input the number of the
step point. Since this is the initial step point, the available devices are S0~S9
(choose the desired device by click on the “Up” and “Down” key right of the cell
or simply type the device you want). If the number you choose is not within the
range of 0~9, the “S exceeds usage range (S0~S9)” warning message will pop
up. Besides, when entering the device number, it does not matter if device name
“S” does not input since it will be added automatically in SFC mode. After the
numbering is completed, press Enter key on the keyboard, or left click your
mouse twice, or simply move the editing block away.