1. Alternative convergence:
Move from S30, S31, and S32 to the
same step point, S40 according to the
individual transition condition.
Step 10: After divergence, if you have to converge the step points, use alternative
Step 11: If the convergence is consisted of more than two points, users can press
(
line for simultaneous connection diagram,
convergence diagram,
diagram)
function keys (Shift) + (F1~F9) to add more points for the convergence.
convergence of condition diagram (press the function key [F7], or click the icon
convergence diagram (press the function key [F9], or click the icon
SFC toolbar) for simultaneous connection. After that, users can then edit the
internal program of every step point diagram. Move the editing block to where
the initial step point diagram located, and right click your mouse to select the
“Inner Ladder Mode” from the pop-up menu (Refer to Step 2 and Step 3).
: Auxiliary line for simultaneous convergence diagram,
on SFC toolbar) for alternative connection and use simultaneous
,
: Auxiliary line for alternative connection
2. Simultaneous convergence:
Move from S30, S31, and S32 to the
same step point, S40 according to the
same transition condition.
: Auxiliary line for alternative
,
8 SFC Mode
: Auxiliary
on
8-11