CS8952-CQ Cirrus Logic Inc, CS8952-CQ Datasheet - Page 50

no-image

CS8952-CQ

Manufacturer Part Number
CS8952-CQ
Description
IC ETHNT 10/100 TXRX 5V 100-TQFP
Manufacturer
Cirrus Logic Inc
Type
Transceiverr
Datasheet

Specifications of CS8952-CQ

Mounting Type
Surface Mount
Protocol
MII
Voltage - Supply
4.75 V ~ 5.25 V
Package / Case
100-TQFP, 100-VQFP
Peak Reflow Compatible (260 C)
No
Supply Voltage
5V
Supply Voltage Max
5V
Transceiver Type
Ethernet
Leaded Process Compatible
No
No. Of Drivers
6
Interface Type
MII
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Drivers/receivers
-
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Contains lead / RoHS non-compliant
Other names
598-1205

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS8952-CQ
Quantity:
5 510
Part Number:
CS8952-CQ
Manufacturer:
NEC
Quantity:
5 510
Part Number:
CS8952-CQ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS8952-CQ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS8952-CQZ
Manufacturer:
CIRRUS
Quantity:
921
Part Number:
CS8952-CQZ
Manufacturer:
CS
Quantity:
745
Part Number:
CS8952-CQZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS8952-CQZR
Manufacturer:
CIRRUS
Quantity:
17
Part Number:
CS8952-CQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
6.13
50
15
14:11 Reserved
10:0
BIT
Load
15
7
Load
Scrambler Initializa-
tion Key
Scrambler Key Initialization Register - Address 14h
NAME
14
6
Read/Set
Read Only 0000
Read/Write Reset value is
TYPE
13
5
Reserved
0
dependent on the
PHY Address field
of the Self Status
Register (address
19h).
Scrambler Initialization Key
RESET
12
4
CrystalLAN™ 100BASE-X and 10BASE-T Transceiver
When this bit is set, the scrambler will be loaded with
the value in the Scrambler Initialization Key field.
When the load is complete, this bit will clear automat-
ically.
These bits should be read as don’t cares and, when
written, should be written to 0.
This field allows the Scrambler to be loaded with a
user-definable key sequence. A value of 000h has
the effect of bypassing the scrambler function.
This is valuable for testing purposes to allow a deter-
ministic response to test stimulus without a synchro-
nization delay.
Note: This field is disabled, and writes to this bit are
ignored when the National Compatibility Mode bit of
the 10BASE-T Configuration Register (address 1Ch)
is set.
11
3
10
2
DESCRIPTION
Scrambler Initialization Key
9
1
CS8952
8
0

Related parts for CS8952-CQ