TDA5230XT Infineon Technologies, TDA5230XT Datasheet - Page 110

no-image

TDA5230XT

Manufacturer Part Number
TDA5230XT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TDA5230XT

Operating Temperature (min)
-40C
Operating Temperature (max)
105C
Operating Temperature Classification
Industrial
Product Depth (mm)
4.4mm
Product Length (mm)
9.7mm
Lead Free Status / Rohs Status
Compliant
TDA523x
Functional Description
clock recovery reset
start point
valid data
valid data
TSI A
TSI GAP
TSI B
RUNIN
GAPSync
< 1bit
< 1bit
PLL sync
internal PLL sync
Figure 54
Clock Recovery GAP Re-synchronization Mode 1
When the time TSI GAP in the start sequence of the transmitted telegram has elapsed,
the receiver needs a certain time (GAPSync = 5...6 chips) to readjust the PLL settings.
Behavior of the system at the starting position of the TSI B:
The starting position (TSI B start) for the TSI B comparison is independent from the
RUNIN settings (CDR2 register) and the Re-synchronization mode (TSIMODE register):
[
]
[
]
TSIBstart chips
=
TSIGAP chips
+
6…8
The incoming chips at TSI B start and the following incoming chips are compared with
the contents of the register TSI B. Please notice that the receiver’s PLL runs at the data
rate determined before the gap. Therefore, the receiver calculates the gap based on this
data rate.
Behavior of the system at the ending position of TSI B:
The system checks for the TSI B to match within a limited time. If there is no match within
this time, then the receiver starts again to search for the TSI A pattern at the following
incoming chips:
[
]
[
]
[
]
TSIBstop chips
=
TSIGAP chips
+
TSILENB chips
+
11
For a successful TSI B pattern match, the defined TSI B pattern must be between “Start
of TSIB” and “Stop of TSI B”. In the example below, the earliest possible start position
th
nd
would be the 18
chip and the latest possible start position would be the 22
chip.
Please note that after a gap the internal TSI comparison register is cleared (all chips set
to ’0’). In this case, a TSI B criteria of “0000” would always match at the beginning. To
avoid such an unwanted matching, set the highest TSI B match chip to ’1’.
Data Sheet