TDA5230XT Infineon Technologies, TDA5230XT Datasheet - Page 117

no-image

TDA5230XT

Manufacturer Part Number
TDA5230XT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TDA5230XT

Operating Temperature (min)
-40C
Operating Temperature (max)
105C
Operating Temperature Classification
Industrial
Product Depth (mm)
4.4mm
Product Length (mm)
9.7mm
Lead Free Status / Rohs Status
Compliant
It is possible to choose which part of the incoming data stream is compared against the
stored MIDs. The register MIDC0 contains the Scan Start Position (Bit 0 to Bit 127). If
the Bit Counter detects the Scan Start Position the Control FSM enables the Scanner.
The register MIDC1 contains the number of bytes to scan (Byte 0 to Byte 3). During the
observation period, the Message ID Scanning is aborted immediately by the Master FSM
if symbol synchronization is lost or an EOM (End Of Message) is detected.
Example:
Start Selection: 0010001b
Number to scan: 00b, 01b, 10b, 11b
Figure 59
The starting position in this case is Bit 17. Depending on the number to scan, the
corresponding number of bytes is compared with the stored MIDs.
Dual:
ADDR:
Dual:
ADDR:
Data Sheet
FSYNC
7:0
6:0
Bit R/W Description
Bit R/W Description
Number To Scan=00b
Number To Scan=01b
Number To Scan=10b
Number To Scan=11b
Bit
AMID0-AMID19
W
AMIDC0
W
0x29-0x3C
0x3D
0
1
MID0: Message ID Register
SP: MID scan start position
Min: 00h = Comparison starts one bit after FSYNC
Max: 7F = Comparison starts 128 bits after FSYNC
and
2
ID Scanning
and BMIDC0:
0x5E
and
17 18
Start MID Scan
0x4A-0x5D
and BMID0-BMID19:
Byte0
Byte0
Byte0
Byte0
24 25 26 27
Conf.A Message ID Control Register0
Byte1
Byte1
Byte1
113
33 34 35 36
Conf.A Message ID Register0
Byte2
Byte2
42 43 44 45
Functional Description
Reset Value:0x00
Reset Value:0x00
Version 4.0, 2007-06-01
Byte3
TDA523x
51 52 53

Related parts for TDA5230XT