PEB20320H-V34RF Infineon Technologies, PEB20320H-V34RF Datasheet - Page 131

no-image

PEB20320H-V34RF

Manufacturer Part Number
PEB20320H-V34RF
Description
IC CONTROLR 32-CH HDLC 160-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20320H-V34RF

Function
Multichannel Network Interface Controller (MUNICH)
Interface
HDLC, ISDN, V.110, X.30
Voltage - Supply
5V
Current - Supply
100mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
160-BSQFP
Includes
Automatic Flag Detection, CRC Generation and Checking, Error Detection, Interframe-Time-Fill Change Detection
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Power (watts)
-
Number Of Circuits
-
Other names
PEB20320H-V34RF
PEB20320H-V34RFIN
3
3.1
Upon reset MUNICH32 is set to its initial state. The active high system reset clears the
internal logic and causes MUNICH32 to tristate all output lines. Channel processing is
deactivated. After reset all buffers are empty and no buffer size of TB is allocated to the
channels. The DMA controller state is set to the hold condition for all link lists. The
descriptor and data pointers remain at a random value.
The bits RO and TO are set to ‘1’ and RA and TA are set to ‘0’ for all logical channels by
reset. All time slots are connected to the logical channel 0 and the following configuration
is set:
Action Specification
LOC = LOOP = LOOPI = 0
PCM = T1/DS1
MFL = 0
Time Slot Assignment
fill/mask = 00
RTI, TTI = 0
channel number = 00
Channel Specification
MODE = 00, i.e. TMA
FA = 0
IFTF = 0
CRC = 0
INV = 0
TRV = 00,
RA = 0
TA = 0
TH = 0
User’s Manual
RO = 1
TO = 1
Operational Description
Reset State
H
, i.e. all bits masked/set to ‘1’
24-channel 1.536 Mbit/s (000)
H
131
Operational Description
PEB 20320
01.2000

Related parts for PEB20320H-V34RF