PEB20320H-V34RF Infineon Technologies, PEB20320H-V34RF Datasheet - Page 170

no-image

PEB20320H-V34RF

Manufacturer Part Number
PEB20320H-V34RF
Description
IC CONTROLR 32-CH HDLC 160-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20320H-V34RF

Function
Multichannel Network Interface Controller (MUNICH)
Interface
HDLC, ISDN, V.110, X.30
Voltage - Supply
5V
Current - Supply
100mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
160-BSQFP
Includes
Automatic Flag Detection, CRC Generation and Checking, Error Detection, Interframe-Time-Fill Change Detection
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Power (watts)
-
Number Of Circuits
-
Other names
PEB20320H-V34RF
PEB20320H-V34RFIN
User’s Manual
BNO:
Status:
HDLC CS = 0
HDLC CS = 1
V.110/X.30
TMB
TMR
TMA
Where ‘0’ means that in the corresponding mode the bit is always ‘0’. It should not be
interpreted though to be upward compatible to future versions.
0
0
7
0
0
0
0
0
• for HDLC, TMB, TMR if the end of a frame was stored in the receive data
• for V.110/X.30 mode if the 3 contiguous frames with errors in the
• for V.110/X.30 mode if the data could not be transferred to the shared
MUNICH32 writes the number of data bytes it has stored in the current data
section into BNO.
The MUNICH32 writes the status information into the status byte whenever it
sets the C-bit. If the status information is not 00 or 40 an interrupt with ERR
bit set is generated. The status is then a means to locate or analyze the
receive error.
The following table gives a general overview over the different status bits in
relation to the channel modes.
section
(interrupt with set FI bit is generated)
synchronization pattern are received
interrupt with set ERR bit
memory due to RB buffer inaccessibility
status = 21 interrupt with set ERR bit.
C indicates that the second long word of the receive descriptor was written
by the MUNICH32. Afterwards the MUNICH32 writes the next receive
descriptor address into CCS. Then it branches to this descriptor
immediately.
SF
6
NI
0
0
0
0
0
FE = 1, status gives the receive status determined by RD
LOSS
0
0
I
0
0
0
5
CRCO
ILN
ILN
0
0
0
0
4
170
NOB
3
IL
IL
0
IL
IL
0
FE = 0, status = 20 or status = 21
Detailed Register Description
LFD
I
I
0
I
I
0
2
FE = 0, status = 01 or
RA
1
I
I
IF
IF
IF
IF
PEB 20320
ROF
01.2000
0
I
I
I
I
I
0

Related parts for PEB20320H-V34RF