modulation mode.
Fast Initiate
On receiving the Fast Initiate command, the M24LR64-R will set the internal Initiate_flag
and send back a response only if it is in the Ready state. The command has to be issued in
the Non Addressed mode only (Select_flag is reset to 0 and Address_flag is reset to 0). If an
error occurs, the M24LR64-R does not generate any answer. The Initiate_flag is reset after
a power off of the M24LR64-R. The data rate of the response is multiplied by 2.
The request contains:
Table 89.
The response contains:
Table 90.
Figure 68. Fast Initiate frame exchange between VCD and M24LR64-R
NRT
Response
Request
M24LR64-
SOF
SOF
and t
No data
the flags
the Unique ID
VCD
R
SOF
Request_flags
Response
Fast Initiate request format
Fast Initiate response format
are dependent on the M24LR64-R-to-VCD data rate and subcarrier
_flags
8 bits
SOF
8 bits
Fast Initiate request
DSFID
8 bits
Initiate
Doc ID 15170 Rev 8
Fast
C2h
IC Mfg
Code
02h
EOF
64 bits
UID
<-t
1
-> SOF Fast Initiate response EOF
CRC16
16 bits
CRC16
16 bits