XE8000EV120 Semtech, XE8000EV120 Datasheet - Page 82

BOARD EVAL FOR SX8722I070TRLF

XE8000EV120

Manufacturer Part Number
XE8000EV120
Description
BOARD EVAL FOR SX8722I070TRLF
Manufacturer
Semtech
Series
ZoomingADC™r
Datasheets

Specifications of XE8000EV120

Number Of Adc's
1
Number Of Bits
16
Data Interface
I²C
Inputs Per Adc
7 Single or 4 Differential
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 125°C
Utilized Ic / Part
SX8722
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
XM8000EV120
XM8000EV120
14.2. Register description
The register descriptions are presented here in ascending order of Register Address. Some registers carry several individual
data fields of various sizes; from single-bit values (e.g. flags), upwards. Some data fields are spread across multiple
registers. Unused bits are 'don't care' and writing either 0 or 1 will not affect any function of the device. After power on reset
the registers will have the values indicated in the tables "Reset" column.
14.2.1. SX8722 general configuration
ACS - Revision 4.2
©2008 Semtech Corp.
ADVANCED COMMUNICATIONS & SENSING
7:4
7:4
Bit
Bit
Bit
7
6
5
4
3
2
1
0
3
2
1
0
3
2
1
EE_D
XTAL_D
CKOUT
RESERVED
EE
SLEEP
SHUT
CAL
reserved
AL1OnC
AL1OffC
AL2OnC
AL2OffC
reserved
CONF4
CONF3
CONF2
Bit Name
Bit name
Name
October 2008
r
r
rw
rw
r
rw
rw
r
r
rw
rw
rw
rw
r
rw
rw
rw
Mode
Mode
Mode
Table 60. SXCtrl1 (0x00)
Table 61. SXCtrl2 (0x01)
Reset
Reset
Reset
0
0
0
0
0
0
0
0
0
0
0
0
x
x
0
x
x
Page 82
Indicates if an EEPROM was detected at startup
Indicates if an XTAL was detected at startup
Enabled the clock output on CKOUT pin
Is set to 1 when SX8722 loaded its configuration from the
EEPROM at startup.
When set to 1 his bit activates the Sleep mode of the SX8722.
Setting pin SLEEP to 1 has the same effect.
When set to 1 his bit activates the Shutdown mode of the
SX8722. Setting pin SHUT to 1 has the same effect.
This flag shows if the SX8722 clock has been successfully
calibrated.
Sets the logical condition for alarm 1 on (0 = OR, 1 = AND)
Sets the logical condition for alarm 1 off (0 = OR, 1 = AND)
Sets the logical condition for alarm 2 on (0 = OR, 1 = AND)
Sets the logical condition for alarm 2 off (0 = OR, 1 = AND)
Configuration 4 enabling
Configuration 3 enabling
Configuration 2 enabling
High gain acquisition for sensor interface
Description
Description
Description
DATASHEET
www.semtech.com
SX8722

Related parts for XE8000EV120