ATTINY20-EK1 Atmel, ATTINY20-EK1 Datasheet - Page 62

no-image

ATTINY20-EK1

Manufacturer Part Number
ATTINY20-EK1
Description
KIT EVAL TOUCH ATTINY20
Manufacturer
Atmel
Datasheet

Specifications of ATTINY20-EK1

Sensor Type
*
Sensing Range
*
Interface
*
Sensitivity
*
Voltage - Supply
*
Embedded
*
Utilized Ic / Part
*
Silicon Manufacturer
Atmel
Core Architecture
AVR
Core Sub-architecture
TinyAVR
Kit Contents
Board
Svhc
No SVHC (15-Dec-2010)
Mcu Supported Families
ATtiny20
Tool / Board Applications
Microcontroller
Rohs Compliant
Yes
Tool Type
Development Kit
Cpu Core
AVR 8
Data Bus Width
8 bit
Processor To Be Evaluated
ATtiny20
Interface Type
Touch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
11.5
62
Output Compare Unit
ATtiny20
Figure 11-2. Counter Unit Block Diagram
Signal description (internal signals):
Depending of the mode of operation used, the counter is cleared, incremented, or decremented
at each timer clock (clk
selected by the Clock Select bits (CS0[2:0]). When no clock source is selected (CS0[2:0] = 0)
the timer is stopped. However, the TCNT0 value can be accessed by the CPU, regardless of
whether clk
count operations.
The counting sequence is determined by the setting of the WGM01 and WGM00 bits located in
the Timer/Counter Control Register (TCCR0A) and the WGM02 bit located in the Timer/Counter
Control Register B (TCCR0B). There are close connections between how the counter behaves
(counts) and how waveforms are generated on the Output Compare output OC0A. For more
details about advanced counting sequences and waveform generation, see
tion” on page
The Timer/Counter Overflow Flag (TOV0) is set according to the mode of operation selected by
the WGM0[1:0] bits. TOV0 can be used for generating a CPU interrupt.
The 8-bit comparator continuously compares TCNT0 with the Output Compare Registers
(OCR0A and OCR0B). Whenever TCNT0 equals OCR0A or OCR0B, the comparator signals a
match. A match will set the Output Compare Flag (OCF0A or OCF0B) at the next timer clock
cycle. If the corresponding interrupt is enabled, the Output Compare Flag generates an Output
Compare interrupt. The Output Compare Flag is automatically cleared when the interrupt is exe-
cuted. Alternatively, the flag can be cleared by software by writing a logical one to its I/O bit
location. The Waveform Generator uses the match signal to generate an output according to
operating mode set by the WGM0[2:0] bits and Compare Output mode (COM0x[1:0]) bits. The
max and bottom signals are used by the Waveform Generator for handling the special cases of
the extreme values in some modes of operation. See
count
direction
clear
clk
top
bottom
Tn
DATA BUS
T0
TCNTn
65.
is present or not. A CPU write overrides (has priority over) all counter clear or
T0
). clk
Increment or decrement TCNT0 by 1.
Select between increment and decrement.
Clear TCNT0 (set all bits to zero).
Timer/Counter clock, referred to as clk
Signalize that TCNT0 has reached maximum value.
Signalize that TCNT0 has reached minimum value (zero).
T0
can be generated from an external or internal clock source,
direction
count
clear
bottom
Control Logic
top
“Modes of Operation” on page
TOVn
(Int.Req.)
clk
Tn
Clock Select
( From Prescaler )
T0
Detector
Edge
in the following.
“Modes of Opera-
8235B–AVR–04/11
65.
Tn