HD64F3687GFPV Renesas Electronics America, HD64F3687GFPV Datasheet - Page 316

IC H8 MCU FLASH 56K 64LQFP

HD64F3687GFPV

Manufacturer Part Number
HD64F3687GFPV
Description
IC H8 MCU FLASH 56K 64LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheets

Specifications of HD64F3687GFPV

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, SCI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
45
Program Memory Size
56KB (56K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
64-LQFP
Package
64LQFP
Family Name
H8
Maximum Speed
20 MHz
Operating Supply Voltage
3.3|5 V
Data Bus Width
16|32 Bit
Number Of Programmable I/os
45
Interface Type
I2C/SCI
On-chip Adc
8-chx10-bit
Number Of Timers
3
For Use With
R0K436079S000BE - KIT DEV FOR H8/36079 W/COMPILER
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3687GFPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3687GFPV
Manufacturer:
RENESAS
Quantity:
1 000
Section 16 Serial Communication Interface 3 (SCI3)
Rev.5.00 Nov. 02, 2005 Page 282 of 500
REJ09B0027-0500
(A)
Yes
No
Figure 16.8 Sample Serial Reception Data Flowchart (Asynchronous Mode) (1)
Read receive data in RDR
Clear RE bit in SCR3 to 0
Read RDRF flag in SSR
Read OER, PER, and
OER+PER+FER = 1
All data received?
FER flags in SSR
Start reception
RDRF = 1
<End>
Yes
No
No
(Continued on next page)
Error processing
[1]
Yes
[2]
[3]
[4]
[1] Read the OER, PER, and FER flags in
[2] Read SSR and check that RDRF = 1,
[3] To continue serial reception, before the
[4] If a receive error occurs, read the OER,
The RDRF flag is cleared automatically.
SSR to identify the error. If a receive
error occurs, performs the appropriate
error processing.
then read the receive data in RDR.
The RDRF flag is cleared automatically.
stop bit for the current frame is
received, read the RDRF flag and read
RDR.
PER, and FER flags in SSR to identify
the error. After performing the
appropriate error processing, ensure
that the OER, PER, and FER flags are
all cleared to 0. Reception cannot be
resumed if any of these flags are set to
1. In the case of a framing error, a
break can be detected by reading the
value of the input port corresponding to
the RxD pin.

Related parts for HD64F3687GFPV