AT32UC3B0256-A2UR Atmel, AT32UC3B0256-A2UR Datasheet - Page 246

MCU AVR32 256K FLASH 64-TQFP

AT32UC3B0256-A2UR

Manufacturer Part Number
AT32UC3B0256-A2UR
Description
MCU AVR32 256K FLASH 64-TQFP
Manufacturer
Atmel
Series
AVR®32 UC3r
Datasheet

Specifications of AT32UC3B0256-A2UR

Package / Case
64-TQFP, 64-VQFP
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Operating Temperature
-40°C ~ 85°C
Speed
60MHz
Number Of I /o
44
Core Processor
AVR
Program Memory Type
FLASH
Ram Size
32K x 8
Program Memory Size
256KB (256K x 8)
Data Converters
A/D 8x10b
Oscillator Type
Internal
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Connectivity
I²C, IrDA, SPI, SSC, UART/USART, USB
Core Size
32-Bit
Package
64TQFP
Device Core
AVR32
Family Name
AT32
Maximum Speed
60 MHz
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Number Of Programmable I/os
44
Interface Type
I2S/SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Number Of Timers
3
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3B0256-A2UR
Manufacturer:
Atmel
Quantity:
10 000
19.14.1
Name:
Access:
Offset:
Reset Value: 0x00000000
• SWRST: Software Reset
• SVDIS: TWI Slave Mode Disabled
• SVEN: TWI Slave Mode Enabled
• MSDIS: TWI Master Mode Disabled
• MSEN: TWI Master Mode Enabled
• STOP: Send a STOP Condition
• START: Send a START Condition
32059K–03/2011
SWRST
31
23
15
7
0 = No effect.
1 = Equivalent to a system reset.
0 = No effect.
1 = The slave mode is disabled. The shifter and holding characters (if it contains data) are transmitted in case of read operation.
In write operation, the character being transferred must be completely received before disabling.
0 = No effect.
1 = If SVDIS = 0, the slave mode is enabled.
Switching from Master to Slave mode is only permitted when TXCOMP = 1.
0 = No effect.
1 = The master mode is disabled, all pending data is transmitted. The shifter and holding characters (if it contains data) are
transmitted in case of write operation. In read operation, the character being transferred must be completely received before
disabling.
0 = No effect.
1 = If MSDIS = 0, the master mode is enabled.
Switching from Slave to Master mode is only permitted when TXCOMP = 1.
0 = No effect.
1 = STOP Condition is sent just after completing the current byte transmission in master read mode.
0 = No effect.
1 = A frame beginning with a START bit is transmitted according to the features defined in the mode register.
- In single data byte master read, the START and STOP must both be set.
- In multiple data bytes master read, the STOP must be set after the last data received but one.
- In master read mode, if a NACK bit is received, the STOP is automatically performed.
- In multiple data write operation, when both THR and shift register are empty, a STOP condition is automatically sent.
Control Register
CR
Write-only
0x00
30
22
14
6
SVDIS
29
21
13
5
SVEN
28
20
12
4
MSDIS
27
19
11
3
MSEN
26
18
10
2
STOP
25
17
9
1
AT32UC3B
START
24
16
8
0
246