Z8F0813HJ005EG Zilog, Z8F0813HJ005EG Datasheet - Page 142

IC Z8 ENCORE MCU FLASH 8K 28SSOP

Z8F0813HJ005EG

Manufacturer Part Number
Z8F0813HJ005EG
Description
IC Z8 ENCORE MCU FLASH 8K 28SSOP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F0813HJ005EG

Core Processor
Z8
Core Size
8-Bit
Speed
5MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
24
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
28-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Other names
269-4182
Z8F0813HJ005EG
.
PS025203-0405
Flash Code Protection Using the Flash Controller
At Reset, the Flash Controller locks to prevent accidental program or erasure of the Flash
memory. To program or erase the Flash memory, first write the Page Select Register with
the target page. Unlock the Flash Controller by making two consecutive writes to the
Flash Control register with the values
must be rewritten with the same page previously stored there. If the two Page Select writes
do not match, the controller reverts to a locked state. If the two writes match, the selected
page becomes active. See Figure 21 for details.
After unlocking a specific page, the user can enable either Page Program or Erase. Writing
the value
tected. Any other value written to the Flash Control register locks the Flash Controller.
Mass Erase is not allowed in the user code but only in through the Debug Port.
After unlocking a specific page, the user can also write to any byte on that page. After a
byte is written, the page remains unlocked, allowing for subsequent writes to other bytes
on the same page. Further writes to the Flash Control Register cause the active page to
revert to a locked state.
Sector Based Flash Protection
The final protection mechanism is implemented on a per-sector basis. The Flash memories
of Z8 Encore!
the total size of the Flash memory, unless this value is smaller than the page size, in which
case the sector and page sizes are equal. On the Z8 Encore!
sector size is 1024 bytes, equal to twice the page size.
The Sector Protect Register controls the protection state of each Flash sector. This register
is shared with the Page Select Register. It is accessed by writing 73H followed by 5EH to
the Flash controller. The next write to the Flash Control Register targets the Sector Protect
Register.
The Sector Protect Register is initialized to 0 on reset, putting each sector into an unpro-
tected state. When a bit in the Sector Protect Register is written to 1, the corresponding
FHSWP
0 or 1
0
95H
Table 78. Flash Code Protection Using the Flash Option Bits
FWP
®
causes a Page Erase only if the active page resides in a sector that is not pro-
0
1
devices are divided into maximum number of 8 sectors. A sector is 1/8 of
Flash Code Protection Description
Programming and erasing disabled for all of Flash Program
Memory. In user code programming, Page Erase, and Mass Erase
are all disabled. Mass Erase is available through the On-Chip
Debugger.
Programming, Page Erase, and Mass Erase are enabled for all of
Flash Program Memory.
P R E L I M I N A R Y
73H
and
8CH
, sequentially. The Page Select Register
Z8 Encore!
®
Z8F0823 Series devices, the
Product Specification
®
Z8F0823 Series
Flash Memory
125