S9S08AW16AE0CFT Freescale Semiconductor, S9S08AW16AE0CFT Datasheet - Page 220

no-image

S9S08AW16AE0CFT

Manufacturer Part Number
S9S08AW16AE0CFT
Description
MCU 16K FLASH AUTO 48-QFN
Manufacturer
Freescale Semiconductor
Series
HCS08r
Datasheet

Specifications of S9S08AW16AE0CFT

Core Processor
HCS08
Core Size
8-Bit
Speed
40MHz
Connectivity
I²C, SCI, SPI
Peripherals
LVD. POR, PWM, WDT
Number Of I /o
38
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
48-QFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S08AW16AE0CFT
Manufacturer:
FREESCALE
Quantity:
20 000
Chapter 13 Inter-Integrated Circuit (S08IICV1)
220
MULT
Field
ICR
7:6
5:0
IIC Multiplier Factor — The MULT bits define the multiplier factor mul. This factor is used along with the SCL
divider to generate the IIC baud rate. The multiplier factor mul as defined by the MULT bits is provided below.
00 mul = 01
01 mul = 02
10 mul = 04
11 Reserved
IIC Clock Rate — The ICR bits are used to prescale the bus clock for bit rate selection. These bits are used to
define the SCL divider and the SDA hold value. The SCL divider multiplied by the value provided by the MULT
register (multiplier factor mul) is used to generate IIC baud rate.
SDA hold time is the delay from the falling edge of the SCL (IIC clock) to the changing of SDA (IIC data). The
ICR is used to determine the SDA hold value.
Table 13-3
be used to set IIC baud rate and SDA hold time. For example:
Table 13-3
hold value of 9.
If the generated SDA hold value is not acceptable, the MULT bits can be used to change the ICR. This will result
in a different SDA hold value.
IIC baud rate = bus speed (Hz)/(mul * SCL divider)
SDA hold time = bus period (s) * SDA hold value
Bus speed = 8 MHz
MULT is set to 01 (mul = 2)
Desired IIC baud rate = 100 kbps
IIC baud rate = bus speed (Hz)/(mul * SCL divider)
100000 = 8000000/(2*SCL divider)
SCL divider = 40
SDA hold time = bus period (s) * SDA hold value
SDA hold time = 1/8000000 * 9 = 1.125 μs
provides the SCL divider and SDA hold values for corresponding values of the ICR. These values can
shows that ICR must be set to 0B to provide an SCL divider of 40 and that this will result in an SDA
Table 13-2. IIC1A Register Field Descriptions
MC9S08AW60 Data Sheet, Rev 2
Description
Freescale Semiconductor

Related parts for S9S08AW16AE0CFT