M30263F6AFP#U5A Renesas Electronics America, M30263F6AFP#U5A Datasheet - Page 46

IC M16C/26A MCU FLASH 42-SSOP

M30263F6AFP#U5A

Manufacturer Part Number
M30263F6AFP#U5A
Description
IC M16C/26A MCU FLASH 42-SSOP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/Tiny/26r
Datasheet

Specifications of M30263F6AFP#U5A

Core Processor
M16C/60
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IEBus, SIO, UART/USART
Peripherals
DMA, PWM, Voltage Detect, WDT
Number Of I /o
33
Program Memory Size
48KB (48K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 10x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
42-SSOP
For Use With
R0K33026AS000BE - KIT DEV EVALUATION M16C/26A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
M
R
R
e
E
1
. v
J
6
Figure 5.1.1.1. Example Reset Circuit
5.2 Software Reset
5.3 Watchdog Timer Reset
5.4 Oscillation Stop Detection Reset
0
C
2
9
2 /
0 .
B
When the PM03 bit in the PM0 register is set to “1” (microcomputer reset), the microcomputer has its pins,
CPU, and SFR initialized. Then the program is executed starting from the address indicated by the reset
vector.
The device will reset using on-chip oscillator as the CPU clock.
At software reset, some SFR’s are not initialized. Refer to “SFR”.
When the PM12 bit in the PM1 register is “1” (reset when watchdog timer underflows), the microcomputer
initializes its pins, CPU and SFR if the watchdog timer underflows.
The device will reset using on-chip oscillator as the system clock. Then the program is executed starting
from the address indicated by the reset vector.
At watchdog timer reset, some SFR’s are not initialized. Refer to “SFR”.
When the CM20 bit in the CM2 register is set to “1”(oscillation stop, re-oscillation detection function
enabled) and the CM27 bit is set to “0” (reset at oscillation stop detection), the microcomputer initializes
its pins, CPU and SFR, coming to a halt if it detects main clock oscillation circuit stop. Refer to the section
“oscillation stop, re-oscillation detection function”.
At oscillation stop detection reset, some SFR’s are not initialized. Refer to the section “SFR”.
0
0
6
2
A
0
F
2
G
e
0 -
b
o r
1 .
2
0
u
, 5
RESET
0
p
2
(
0
M
0
1
7
6
C
2 /
page 27
6
V
, A
CC
M
1
f o
6
C
3
2 /
2
9
6
V
RESET
, B
CC
M
0V
0V
1
6
C
Recommended
operating
voltage
Equal to or less
than 0.2V
2 /
6
) T
CC
More than td(ROC) + td(P-R)
Equal to or less
than 0.2V
CC
5. Reset

Related parts for M30263F6AFP#U5A