D12363VF33V Renesas Electronics America, D12363VF33V Datasheet - Page 672

IC H8S/2363 MCU ROMLESS 128QFP

D12363VF33V

Manufacturer Part Number
D12363VF33V
Description
IC H8S/2363 MCU ROMLESS 128QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12363VF33V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
33MHz
Connectivity
I²C, IrDA, SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
84
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
128-QFP
For Use With
YR0K42378FC000BA - KIT EVAL FOR H8S/2378
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12363VF33V
Manufacturer:
ST
Quantity:
67 000
Part Number:
D12363VF33V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
D12363VF33V
Manufacturer:
RENSAS
Quantity:
20 000
Section 14 Serial Communication Interface (SCI, IrDA)
14.7.7
Data reception in Smart Card interface mode uses the same operation procedure as for normal
serial communication interface mode. Figure 14.29 illustrates the retransfer operation when the
SCI is in receive mode.
1. If an error is found when the received parity bit is checked, the PER bit in SSR is
2. The RDRF bit in SSR is not set for a frame in which an error has occurred.
3. If no error is found when the received parity bit is checked, the PER bit in SSR is not set to 1.
4. The receive operation is judged to have been completed normally, and the RDRF flag in SSR
Figure 14.30 shows a flowchart for reception. The sequence of receive operations can be
performed automatically by specifying the DTC or DMAC to be activated with an RXI interrupt
source. In a receive operation, an RXI interrupt request is generated when the RDRF flag in SSR
is set to 1. If the RXI request is designated beforehand as a DTC or DMAC activation source, the
DTC or DMAC will be activated by the RXI request, and transfer of the receive data will be
carried out. The RDRF flag is cleared to 0 automatically when data transfer is performed by the
DTC or DMAC. If an error occurs in receive mode and the ORER or PER flag is set to 1, a
transfer error interrupt (ERI) request will be generated, and so the error flag must be cleared to 0.
In the event of an error, the DTC or DMAC is not activated and receive data is skipped.
Therefore, receive data is transferred for only the specified number of bytes in the event of an
error. Even when a parity error occurs in receive mode and the PER flag is set to 1, the data that
has been received is transferred to RDR and can be read from there.
Note: For details on receive operations in block transfer mode, refer to section 14.4, Operation in
Rev.6.00 Mar. 18, 2009 Page 612 of 980
REJ09B0050-0600
automatically set to 1. If the RIE bit in SCR is set at this time, an ERI interrupt request is
generated. The PER bit in SSR should be cleared to 0 before the next parity bit is sampled.
is automatically set to 1. If the RIE bit in SCR is set at this time, an RXI interrupt request is
generated.
Asynchronous Mode.
Serial Data Reception (Except for Block Transfer Mode)
RDRF
PER
Ds
D0 D1 D2 D3 D4 D5 D6 D7 Dp DE
Figure 14.29 Retransfer Operation in SCI Receive Mode
nth transfer frame
[2]
[1]
Ds D0 D1 D2 D3 D4 D5 D6 D7 Dp
Retransferred frame
(DE)
[4]
[3]
Ds D0 D1 D2 D3 D4
Transfer
frame n+1

Related parts for D12363VF33V