DF36054FPJ Renesas Electronics America, DF36054FPJ Datasheet - Page 352

MCU 3/5V 32K J-TEMP 64-QFP

DF36054FPJ

Manufacturer Part Number
DF36054FPJ
Description
MCU 3/5V 32K J-TEMP 64-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of DF36054FPJ

Core Processor
H8/300H
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SSU
Peripherals
PWM, WDT
Number Of I /o
45
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
HD64F36054FPJ
HD64F36054FPJ
Section 15 Controller Area Network for Tiny (TinyCAN)
15.3.17 Transmit Error Counter (TEC)
TEC counts the number of transmit message errors on the CAN bus.
Note:
15.3.18 Receive Error Counter (REC)
REC counts the number of receive message errors on the CAN bus.
Note:
Rev. 4.00 Mar. 15, 2006 Page 318 of 556
REJ09B0026-0400
Bit
7
6
5
4
3
2
1
0
Bit
7
6
5
4
3
2
1
0
*
*
Bit Name
TEC7
TEC6
TEC5
TEC4
TEC3
TEC2
TEC1
TEC0
Bit Name
REC7
REC6
REC5
REC4
REC3
REC2
REC1
REC0
TEC can be written to only in test mode (TCR.TSTMD = 1 and TCR.WREC = 1). The
same value should be written to TEC and REC.
REC can be written to only in test mode (TCR.TSTMD = 1 and TCR.WREC = 1). The
same value should be written to TEC and REC.
Initial
Value
0
0
0
0
0
0
0
0
Initial
Value
0
0
0
0
0
0
0
0
R/W
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
R/W*
Description
TEC functions as a counter indicating the number of
transmit message errors on the CAN bus. The count
value is stipulated in the CAN protocol. In normal
operation, TEC can only be read, but can only be
modified by the CDLC. TEC is cleared to 0 by a reset
request (MCR.RSTRQ = 1) or on entering the bus off
state.
TEC can be written to in test mode (TCR.TSTMD = 1 and
TCR.WREC = 1). The same value can be written to both
TEC and REC. TEC should be written to in halt mode. In
other modes, a CAN bus communication error may occur
depending on the TEC value. Note that TEC can be
written to only in test mode.
Description
REC functions as a counter indicating the number of
receive message errors on the CAN bus. The count value
is stipulated in the CAN protocol. In normal operation,
REC can only be read, but can only be modified by the
CDLC. REC is cleared to 0 by a reset request
(MCR.RSTRQ = 1) or on entering the bus off state.
REC can be written to in test mode (TCR.TSTMD = 1 and
TCR.WREC = 1). The same value can be written to both
TEC and REC. REC should be written to in halt mode. In
other modes, a CAN bus communication error may occur
depending on the REC value. Note that REC can be
written to only in test mode.