XRP7740ILB-F Exar Corporation, XRP7740ILB-F Datasheet - Page 22

no-image

XRP7740ILB-F

Manufacturer Part Number
XRP7740ILB-F
Description
IC CTRLR PWM/LDO STP-DWN 40TQFN
Manufacturer
Exar Corporation
Type
Step-Down (Buck)r
Datasheet

Specifications of XRP7740ILB-F

Number Of Outputs
5
Package / Case
40-WFQFN Exposed Pad
Topology
Step-Down (Buck) (4), Linear (1)
Function
Standby Power and GPIOs
Frequency - Switching
1.5MHz
Voltage/current - Output 1
0.9 V ~ 5.1 V, 5A
Voltage/current - Output 2
0.9 V ~ 5.1 V, 15A
Voltage/current - Output 3
0.9 V ~ 5.1 V, 5A
W/led Driver
No
W/supervisor
Yes
W/sequencer
No
Voltage - Supply
6.5 V ~ 20 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Current - Output
5A, 15A
Voltage - Output
0.9 ~ 5.1 V
Voltage - Input
6.5 ~ 20 V
Internal Switch(s)
No
Synchronous Rectifier
Yes
Switching Frequency
300 KHz to 1500 KHz
Operating Supply Voltage
6.5 V to 20 V
Supply Current
50 mA
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Output Voltage
0.9 V to 5.1 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
1016-1352 - EVAL BOARD FOR XRP77401016-1344 - IN-SOCKET PROG BRD VIA USB/GUI
Power - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
1016-1353

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XRP7740ILB-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
REV 1.1.0
PWM Switching Frequency
The PWM switching frequency is set by choosing the corresponding oscillator frequency and clock divider ratio in
the SET_SW_FREQUENCY register. Bits [6:4] set the oscillator frequency and bits [2:0] set the clock divider. The
tables below summarize the available Main Oscillator and PWM switching frequency settings in the XRP7740.
Main Oscillator Frequency
PWM Switching Frequency
There are a number of options that could result in similar PWM switching frequency as shown above. In general,
the chip consumes less power at lower oscillator frequency. When synchronization to external clock is needed,
the user can choose the oscillator frequency to be within +/- 5% of the external clock frequency. A higher Main
Oscillator frequency will not improve accuracy or any performance efficiency.
PWM Switching Frequency Considerations
There are several considerations when choosing the PWM switching frequency.
Minimum On Time
Minimum on time determines the minimum duty cycle at the specific switching frequency. The minimum on time
for the XRP7740 is 40ns.
As an example the minimum duty cycle is 4% for 1MHz PWM frequency. This is important since the minimum on
time dictates the maximum conversion ratio that the PWM controller can achieve.
SET_SW_FREQUENCY[6:4]
Main Oscillator Frequency
Ts
SET_SW_FREQUENCY[2:0]
000
001
010
011
100
101
110
111
EXAR CONFIDENTIAL, PRELIMINARY & PROPRIETARY. DO NOT DISTRIBUTE OR COPY.
EXAR RESERVES THE RIGHT TO MAKE CHANGES TO THIS DATASHEET.
48MHz
000
20.8ns
000
NA
1.5MHz
1.0MHz
750KHz
600KHZ
500KHz
429KHZ
375KHz
Setting the PWM switching frequency
001
44.8MHz 41.6MHz 38.4MHz 35.2MHz
22.3ns
001
NA
1.4MHz
933KHz
700KHz
560KHz
467KHZ
400KHZ
350KHz
Quad-Output Digital PWM Buck Controller
010
24ns
010
NA
1.3MHz
867KHz
650KHz
520KHz
433KHz
370KHz
325KHz
22
SET_SW_FREQUENCY[6:4]
011
26ns
011
NA
1.2MHz
800KHz
600KHz
480KHz
400KHz
343KHz
300KHz
100
28.4ns
100
NA
1.1MHz
733KHz
550KHz
440KHz
367KHz
314KHz
NA
101
32MHz
31.25ns
101
NA
1.0MHz
667KHz
500KHz
400KHz
333KHz
NA
NA
110
28.8Mhz
34.7ns
110
NA
900KHz
600KHz
450KHz
360KHz
300KHz
NA
NA
XRP7740
111
25.6MHz
39ns
111
800KHz
533KHz
400KHz
320KHz
NA
NA
NA
NA

Related parts for XRP7740ILB-F