SX1212IWLTRT Semtech, SX1212IWLTRT Datasheet - Page 51

IC TXRX 300MHZ-510MHZ 32-TQFN

SX1212IWLTRT

Manufacturer Part Number
SX1212IWLTRT
Description
IC TXRX 300MHZ-510MHZ 32-TQFN
Manufacturer
Semtech
Datasheet

Specifications of SX1212IWLTRT

Frequency
300MHz ~ 510MHz
Data Rate - Maximum
150kbps
Modulation Or Protocol
FSK, OOK
Applications
AMR, ISM, Home Automation, Process Control
Power - Output
12.5dBm
Sensitivity
-110dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
3mA
Current - Transmitting
25mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
32-TQFN
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Modulation Type
FSK/OOK
Package Type
TQFN EP
Operating Supply Voltage (min)
2.1V
Operating Supply Voltage (typ)
2.5/3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
SX1212IWLTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1212IWLTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
SX1212IWLTRT
0
Company:
Part Number:
SX1212IWLTRT
Quantity:
16 674
Company:
Part Number:
SX1212IWLTRT
Quantity:
13 674
In Tx mode the packet handler dynamically builds the packet by performing the following operations on the payload
available in the FIFO:
Only the payload (including optional address and length fields) is to be provided by the user in the FIFO.
Assuming that the chip is already in Tx mode then, depending on IRQParam_Tx_start_irq_0 bit, packet
transmission (starting with programmed preamble) will start either after the first byte is written into the FIFO
(Tx_start_irq_0=1) or after the number of bytes written reaches the user defined threshold (Tx_start_irq_0=0). The
FIFO can also be fully or partially filled in Stby mode via PKTParam_Fifo_stby_access. In this case, the start
condition will only be checked when entering Tx mode.
At the end of the transmission (Tx_done = 1), the user must explicitly exit Tx mode if required. (e.g. back to Stby)
Note that while in Tx mode, before and after actual packet transmission (not enough bytes or Tx_done), additional
preamble bytes are automatically sent to the modulator. When the start condition is met, the current additional
preamble byte is completely sent before the transmission of the next packet (i.e. programmed preamble) is started.
In Rx mode the packet handler extracts the user payload to the FIFO by performing the following operations:
Only the payload (including optional address and length fields) is made available in the FIFO.
Payload_ready and CRC_OK interrupts (the latter only if CRC is enabled) can be generated to indicate the end of
the packet reception.
Rev 2 – June 18th, 2009
ADVANCE
Add a programmable number of preamble bytes
Add a programmable Sync word
Optionally calculating CRC over complete payload field (optional length byte + optional address byte +
message) and appending the 2 bytes checksum.
Optional DC-free encoding of the data (Manchester or whitening).
Receiving the preamble and stripping it off.
Detecting the Sync word and stripping it off.
Optional DC-free decoding of data.
Optionally checking the address byte.
Optionally checking CRC and reflecting the result on CRC_status bit and CRC_OK IRQ source.
5.5.3. Tx Processing
5.5.4. Rx Processing
D COMMUNICATIONS & SENSING
1 to 4 bytes
Preamble
Optional User provided fields which are part of the payload
Message part of the payload
Fields added by the packet handler in Tx and processed and removed in Rx
1 to 4 bytes
Figure 44: Variable Length Packet Format
Sync Word
Length
byte
Page 51 of 77
CRC checksum calculation
Address
byte
Optional DC free data coding
Payload/FIFO
0 to (FIFO size - 1) bytes
Message
2-bytes
CRC
www.semtech.com
SX1212

Related parts for SX1212IWLTRT