Specifications of STEVAL-ISV009V1

Design Resources
STEVAL-ISV009V1 BOM STEVAL-ISV009V1 Schematic
Main Purpose
DC/DC, Step Up
Outputs And Type
1, Non-Isolated
Power - Output
-
Voltage - Output
36V
Current - Output
-
Voltage - Input
-
Regulator Topology
Boost
Frequency - Switching
-
Board Type
Fully Populated
Utilized Ic / Part
SPV1020
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-ISV009V1
Manufacturer:
STMicroelectronics
Quantity:
1
AN3392
8
Burst mode
This mode guarantees a correct start-up for SPV1020, avoiding voltage oscillation. After the
power supply connection, the converter starts to work when input voltage becomes higher
than 6.5 V (ULVO_H).
Burst Mode contains 4 internal states, which guarantees to activate gradually phase “1” and
sequentially the four phases. Following diagram shows the FSM of the burst mode (grey
circles are the states of the burst mode).
Each phase is driven with set of 10 “pulses”. Each pulse can be “ON”, driving the phase with
a signal at minimum PWM (DC = 5%), or “OFF”, driving signal completely low.
When activated, a phase is driven with 1 pulse “ON” and 9 “OFF”. Number of “ON” pulses
can be increased up to 10 (in this case, another phase is activated), or decreased up to 0
(the phase is always off).
Increasing or decreasing “ON” pulses depends on the status of the ULVO signal that checks
if input voltage is greater the minimum threshold or not.
Figure 13. Burst mode, FSM
When all the 4 phases are active the system enters the Normal (or MPPT) mode.
Doc ID XXXXX Rev 1
Burst mode
17/52