LAN9313I-NZW SMSC, LAN9313I-NZW Datasheet - Page 102

Ethernet ICs Three Port 10/100 Ethernet Switch

LAN9313I-NZW

Manufacturer Part Number
LAN9313I-NZW
Description
Ethernet ICs Three Port 10/100 Ethernet Switch
Manufacturer
SMSC
Type
Three Port Managed Ethernet Switchr
Datasheet

Specifications of LAN9313I-NZW

Ethernet Connection Type
10 Base-T, 100 Base-TX
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Product
Ethernet Switches
Number Of Transceivers
1
Standard Supported
802.3, 802.3u
Data Rate
10 Mbps, 100 Mbps
Supply Voltage (max)
3.3 V
Supply Voltage (min)
0 V
Supply Current (max)
155 mA, 270 mA
Maximum Operating Temperature
+ 70 C
Package / Case
TQFP-100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9313I-NZW
Manufacturer:
Standard
Quantity:
261
Part Number:
LAN9313I-NZW
Manufacturer:
Microchip Technology
Quantity:
10 000
Revision 1.7 (06-29-10)
8.2.1
EEPROM Controller Operation
I
(E2P_CMD)
In Microwire EEPROM mode, the following operations are supported:
Note: In I
Note: The EEPROM Loader uses the READ command only.
The supported commands of each mode are detailed in
Register (E2P_CMD)," on page
Microwire) are explained in
respectively.
When issuing a WRITE, or WRAL command, the desired data must first be written into the
Data Register
EPC_COMMAND field of the
value. If the operation is a WRITE, the EPC_ADDRESS field in the
(E2P_CMD)
bit of the
when the EPC_BUSY bit is cleared.
When issuing a READ command, the EPC_COMMAND and EPC_ADDRESS fields of the
Command Register (E2P_CMD)
address, respectively. The READ command is executed by setting the EPC_BUSY bit of the
Command Register
bit is cleared, at which time the data from the EEPROM may be read from the
(E2P_DATA).
Other EEPROM operations (EWDS, EWEN, ERASE, ERAL, RELOAD) are performed by writing the
appropriate command into the EPC_COMMAND field of the
(E2P_CMD). The command is executed by setting the EPC_BUSY bit of the
Register
modifying the
Note: The EEPROM device powers-up in the erase/write disabled state. To modify the contents of
If an operation is attempted and the EEPROM device does not respond within 30mS, the
LAN9313/LAN9313i will time-out, and the EPC_TIMEOUT bit of the
(E2P_CMD)
2
C and Microwire master EEPROM operations are performed using the
ERASE (Erase Location)
ERAL (Erase All)
EWDS (Erase/Write Disable)
EWEN (Erase/Write Enable)
READ (Read Location)
WRITE (Write Location)
WRAL (Write All)
RELOAD (EEPROM Loader Reload - See
are supported.
the EEPROM, the EWEN command must first be issued.
EEPROM Command Register (E2P_CMD)
(E2P_CMD). In all cases, the software must wait for the EPC_BUSY bit to clear before
2
C EEPROM mode, only a sub-set of the above commands (READ, WRITE, and RELOAD)
must also be set to the desired location. The command is executed when the EPC_BUSY
and
will be set.
EEPROM Command Register
(E2P_DATA). The WRITE or WRAL command may then be issued by setting the
EEPROM Data Register
(E2P_CMD). The completion of the operation is indicated when the EPC_BUSY
Section 8.2.2, "I2C EEPROM"
EEPROM Command Register (E2P_CMD)
must be configured with the desired command value and the read
160. Details specific to each EEPROM controller mode (I
DATASHEET
102
(E2P_DATA).
(E2P_CMD).
Section 8.2.4, "EEPROM
is set. The completion of the operation is indicated
and
Section 13.1.3.1, "EEPROM Command
Three Port 10/100 Managed Ethernet Switch with MII
Section 8.2.3, "Microwire EEPROM"
EEPROM Command Register
EEPROM Command Register
EEPROM Command Register
EEPROM Command Register
Loader")
to the desired command
EEPROM Data Register
SMSC LAN9313/LAN9313i
EEPROM Command
EEPROM
EEPROM
EEPROM
Datasheet
2
C and

Related parts for LAN9313I-NZW