E53-COV04 Omron, E53-COV04 Datasheet - Page 11

no-image

E53-COV04

Manufacturer Part Number
E53-COV04
Description
E5CJ TERMINAL COVER
Manufacturer
Omron
Datasheet

Specifications of E53-COV04

Accessory Type
Terminal Cover
For Use With/related Products
E5CJ
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E53COV04
Specifications
1-3-2 Characteristics
E5jJ
6
Indication accuracy
Hysteresis (for ON/OFF control)
Proportional band
Integral time
Derivative time
Control period
Manual reset value (I = 0)
Alarm setting range
Sampling period
Output refresh period
Display refresh period
Insulation resistance
Dielectric strength
Vibration
resistance
Shock resistance
Weight
Enclosure rating
Memory Protection
EMC
Approved standards
i
Item
Malfunction
Destruction
Malfunction
Destruction
E5AJ
E5EJ
E5CJ
Note
Thermocouple K, T, or N at a temperature of –100 C; thermocouple U at
digit max.
0.1 to 999.9 C/ F (in units of 0.1 C/ F)
0.1 to 999.9 C/ F (in units of 0.1 C/ F)
0 to 3999 s (in units of 1 s)
0 to 3999 s (in units of 1 s)
Relay or voltage output:1 to 99 s (in units of 1 s)
0.0 to 100.0% (in units of 0.1%)
With K, J, L, or N input: –1999 to 9999 C/ F (in units of 1 C/ F)
With JPt100, Pt100, T, or U input: –199.9 to 999.9 C/ F (in units of 0.1 C/ F)
500 ms
500 ms
500 ms
20 M min. at 500 VDC (measured with an Output Unit)
2000 VAC, 50/60 Hz for 1 min. between charged terminals different from each other
in polarity
10 to 55 Hz, 9.8 m/s
10 to 55 Hz, 19.6 m/s
196 m/s
294 m/s
Approx. 360 g; mounting bracket: approx. 65 g
Approx. 280 g; mounting bracket: approx. 65 g
Approx. 170 g; adapter: approx. 10 g
Front panel:
Rear case:
Terminals:
Non-volatile memory
Emission Enclosure:
Emission AC Mains:
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance: ENV50141:
Immunity Burst:
UL1092, CSA C22.2 No. 142
Conforms to EN50081-2, EN50082-2, EN61010-1 (IEC1010-1) (see note 2)
Conforms to VDE0106/part 100 (Finger Protection), when the separately-ordered
terminal cover is mounted.
1. The model numbers of the exclusive watertight covers conforming to IP66,
2. Basic insulation is between the input and output.
0.5% or 1 C whichever is larger
NEMA4 are as follows:
For E5AJ: Y92A-96N; For E5CJ: Y92A-48N; For E5EJ: Y92A-49N
2
2
(20G) 3 times each in 3-axis 6 directions (98 m/s
(30G) 3 times each in 3-axis 6 directions
IEC standard IP20
E5AJ/E5EJ: IEC standard IP54
E5CJ: IEC standard IP50 (see note 1)
IEC standard IP00
2
2
(1G) 10 min. in X, Y, and Z directions
(2G) 2 hr. in X, Y, and Z directions
Specification
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61000-4-2: 4 kV contact discharge (level 2)
ENV50140:
EN61000-4-4: 2 kV power-line (level 3)
1 digit max.
8 kV air discharge (level 3)
80 MHz to 1 GHz) (level 3)
10 V/m (pulse modulated,
900 MHz)
2 kV I/O signal-line (level 4)
10 V/m (amplitude modulated,
10 V (0.15 to 80 MHz) (level 3)
2
(10G) for the relay)
Section 1-3
2 C
1