E53-COV04 Omron, E53-COV04 Datasheet - Page 26

no-image

E53-COV04

Manufacturer Part Number
E53-COV04
Description
E5CJ TERMINAL COVER
Manufacturer
Omron
Datasheet

Specifications of E53-COV04

Accessory Type
Terminal Cover
For Use With/related Products
E5CJ
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E53COV04
Parameters on Display Level 1
3-5
Parameters on Display Level 1
Note
1. Displayed if the initial value is changed on the engineering level.
2. Not displayed if current output is used as control output or a model with no
heater burnout alarm function is used.
(Input shift value setting)
(Output value display)
(Control period setting)
(Set point 0 setting)
(Set point 1 setting)
(Set point 2 setting)
(Set point 3 setting)
(Heater current value
display)
(Heater burnout alarm
value setting)
(Proportional
band setting)*
(Integral time setting)
(Derivative time setting)
(Manual reset value
setting)
*In case of F:
The value set before
shipping appears
(Hysteresis setting)
Displays when the E5jJ in PID control
operation has a relay or voltage output.
Displays if I is 0.
Displays when the E5jJ is in ON/
OFF control operation.
Displays if the input shift value dis-
play is selected (see note 1).
Displays when the E5jJ in ad-
vanced PID operation.
Displays only if the event input 2
function is used for set point selec-
tion (see note 1).
Displays if the heater burnout
alarm function is selected. (see
note 2).
Displays if the E5jJ has an
event input.
Section 3-5
23