E53-COV04 Omron, E53-COV04 Datasheet - Page 40

no-image

E53-COV04

Manufacturer Part Number
E53-COV04
Description
E5CJ TERMINAL COVER
Manufacturer
Omron
Datasheet

Specifications of E53-COV04

Accessory Type
Terminal Cover
For Use With/related Products
E5CJ
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E53COV04
Terminal Arrangement
5-3
E5AJ/E5EJ Standard Model
E5AJ/E5EJ with Communications Function
38
100 to 240 VAC, 50 or 60 Hz, 14 VA
or
24 VAC, 50 or 60 Hz, 10 VA
24 VDC 6 W
100 to 240 VAC, 50 or 60 Hz, 14 VA
or
24 VAC, 50 or 60 Hz, 10 VA
24 VDC 6 W
See note 2.
See note 1.
Alarm output 2
See note 1.
Alarm output 2
See note 3.
Terminal Arrangement
Alarm output 1
(Heater burnout
alarm and tem-
perature alarm)
Alarm output 1
(Heater burnout
alarm and tem-
perature alarm)
Control output
Control output
(ALM2)
(ALM1)
(ALM2)
(ALM1)
Note
Note
1. The E53-C cannot be used.
2. The event input terminals and voltage output and current output terminals
3. Only the heater burnout alarm will be output from the alarm output 1 termi-
1. The E53-C cannot be used.
10
10
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
are not insulated.
nals if alarm mode switch 1 is set to 0. Only the temperature alarm will be
output if the heater burnout alarm value is set to 0.0 A.
8
7
8
7
8
7
8
7
8
7
8
7
8
7
8
7
Relay Output Unit
Relay Output Unit
Current Output Unit
Voltage Output Unit
250 VAC
3A
250 VAC
3A
Current Output Unit
Voltage Output Unit
250 VAC
3A
250 VAC
3A
+53-C3
– (600
+53-C3
– (600
+E53-Q
– 40 mA max.
+E53-Q3
– 24 VDC
+E53-Q
– (40 mA max.)
+E53-Q3
– 24 VDC
4 to 20 mA DC
E53-R
250 VAC
5 A
4 to 20 mA DC
12 VDC
(20 mA max.)
E53-R
250 VAC
5 A
12 VDC
(20 mA max.)
Q4
Q4
max.)
max.)
Communications
terminal
Write the name
of the Output
Unit to be used
on the name-
plate on the side
of the case.
Write the name
of the Output
Unit to be used
on the name-
plate on the
side of the
case.
29
27
26
25
22
28
24
23
21
29
27
26
25
22
28
24
23
21
CT
CT
+
+
20
19
18
17
16
15
14
13
12
11
Use the E54-CT1 with a hole diameter of
5.8 mm or E54-CT3 with a hole diameter
of 12 mm (both sold separately).
20
19
18
17
16
15
14
13
12
Use the E54-CT1 with a hole diameter of
5.8 mm or E54-CT3 with a hole diameter
of 12 mm (both sold separately).
11
+
Event input 1 (EV1)
Externally selects the set point.
+
RS-232C
20
29
19
28
18
27
17
26
16
25
Communications terminal
A
B
B
Event input 2 (EV2)
Selects RUN or STOP.
Open
Short-circuit
Open
Short-circuit
A
B
B
RD
SG
SD
SG
RS-422
20
29
19
28
18
27
17
26
16
25
RDB
RDA
SG
SDA
SDB
: Set point 0
: Set point 1
: RUN
: STOP
Section 5-3
See note 2.
RS-485
20
29
19
28
18
27
17
26
16
25
B(+)
A(–)
SG
A(–)
B(+)