MT47H32M16BN-25:D Micron Technology Inc, MT47H32M16BN-25:D Datasheet - Page 125

no-image

MT47H32M16BN-25:D

Manufacturer Part Number
MT47H32M16BN-25:D
Description
Manufacturer
Micron Technology Inc
Type
DDR2 SDRAMr
Datasheet

Specifications of MT47H32M16BN-25:D

Organization
32Mx16
Density
512Mb
Address Bus
15b
Access Time (max)
400ps
Maximum Clock Rate
800MHz
Operating Supply Voltage (typ)
1.8V
Package Type
FBGA
Operating Temp Range
0C to 85C
Operating Supply Voltage (max)
1.9V
Operating Supply Voltage (min)
1.7V
Supply Current
295mA
Pin Count
84
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT47H32M16BN-25:D
Manufacturer:
MICRON
Quantity:
528
Part Number:
MT47H32M16BN-25:D TR
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Table 43: Truth Table – CKE
Notes 1–4 apply to the entire table
PDF: 09005aef82f1e6e2
Rev. M 9/08 EN
Current State
Bank(s) active
All banks idle
Power-down
Self refresh
Previous Cycle
Notes:
(n - 1)
H
H
H
H
L
L
L
L
10. Valid commands for self refresh exit are NOP and DESELECT only.
11. Power-down and self refresh can not be entered while READ or WRITE operations,
12. Minimum CKE high time is
13. Self refresh mode can only be entered from the all banks idle state.
14. Must be a legal command, as defined in Table 36 (page 74).
1. CKE (n) is the logic state of CKE at clock edge n; CKE (n - 1) was the state of CKE at the
2. Current state is the state of the DDR2 SDRAM immediately prior to clock edge n.
3. Command (n) is the command registered at clock edge n, and action (n) is a result of
4. The state of ODT does not affect the states described in this table. The ODT function is
5. Power-down modes do not perform any REFRESH operations. The duration of power-
6. “X” means “Don’t Care” (including floating around Vref) in self refresh and power-
7. All states and sequences not shown are illegal or reserved unless explicitly described else-
8. Valid commands for power-down entry and exit are NOP and DESELECT only.
9. On self refresh exit, DESELECT or NOP commands must be issued on every clock edge
previous clock edge.
command (n).
not available during self refresh (see ODT Timing (page 133) for more details and specif-
ic restrictions).
down mode is therefore limited by the refresh requirements.
down. However, ODT must be driven high or low in power-down if the ODT function is
enabled via EMR.
where in this document.
occurring during the
(200 clocks) is satisfied.
LOAD MODE operations, or PRECHARGE operations are in progress. See SELF REFRESH
(page 121) and SELF REFRESH (page 80) for a list of detailed restrictions.
This requires a minimum of 3 clock cycles of registration.
CKE
Cycle (n)
Current
H
H
H
L
L
L
L
L
t
XSNR period. READ commands may be issued only after
CS#, RAS#, CAS#,
125
DESELECT or NOP
DESELECT or NOP
DESELECT or NOP
DESELECT or NOP
Command (n)
t
CKE = 3 ×
Refresh
WE#
Shown in Table 36 (page 74)
X
X
Micron Technology, Inc. reserves the right to change products or specifications without notice.
t
CK. Minimum CKE LOW time is
512Mb: x4, x8, x16 DDR2 SDRAM
Active power-down en-
Precharge power-down
Maintain power-down
Maintain self refresh
Self refresh entry
Power-down exit
Self refresh exit
Action (n)
entry
try
Power-Down Mode
© 2004 Micron Technology, Inc. All rights reserved.
t
CKE = 3 ×
7, 8, 11, 12
10, 12, 13
7, 9, 10
7, 8, 11
Notes
t
5, 6
7, 8
14
XSRD
6
t
CK.

Related parts for MT47H32M16BN-25:D