BOXD865GLCL Intel, BOXD865GLCL Datasheet - Page 54

no-image

BOXD865GLCL

Manufacturer Part Number
BOXD865GLCL
Description
Manufacturer
Intel
Datasheet

Specifications of BOXD865GLCL

Lead Free Status / Rohs Status
Supplier Unconfirmed
Intel Desktop Board D865GBF/D865GLC Technical Product Specification
1.13.2.2
1.13.2.3
54
Table 18 summarizes the function/operation of the fan connectors.
Table 18.
CAUTION
For LAN wake capabilities, the +5 V standby line for the power supply must be capable of
providing adequate +5 V standby current. Failure to provide adequate standby current when
implementing LAN wake capabilities can damage the power supply.
LAN wake capabilities enable remote wake-up of the computer through a network. The LAN
subsystem PCI bus network adapter monitors network traffic at the Media Independent Interface.
Upon detecting a Magic Packet* frame, the LAN subsystem asserts a wake-up signal that powers
up the computer. Depending on the LAN implementation, the Desktop Boards D865GBF and
D865GLC support LAN wake capabilities with ACPI in the following ways:
Connector
Processor fan
Front chassis fan
Rear chassis fan
For information about
The location of the fan connectors
The location of the fan connectors and sensors for thermal monitoring
The signal names of the fan connectors
The PCI bus PME# signal for PCI 2.2 compliant LAN designs
The onboard LAN subsystem
Fan Connectors
LAN Wake Capabilities
Fan Connector Function/Operation
Description
+12 V DC connection for a processor fan or active fan heatsink.
Fan is on in the S0 or S1 state.
Fan is off when the system is off or in the S3, S4, or S5 state.
Wired to a fan tachometer input of the hardware monitoring and fan control ASIC.
Closed-loop fan control that can adjust the fan speed or switch the fans on or off
as needed.
+12 V DC connection for a system or chassis fan.
Fan is on in the S0 or S1 state.
Fan is off when the system is off or in the S3, S4, or S5 state.
Wired to a fan tachometer input of the hardware monitoring and fan control ASIC.
Closed-loop fan control that can adjust the fan speed or switch the fans on or off
as needed.
+12 V DC connection for a system or chassis fan.
Fan is on in the S0 or S1 state.
Fan is off when the system is off or in the S3, S4, or S5 state.
Wired to a fan tachometer input of the hardware monitoring and fan control ASIC.
Closed-loop fan control that can adjust the fan speed or switch the fans on or off
as needed.
Refer to
Figure 19, page 71
Figure 15, on page 49
Section 2.8.2.2, page 71