TC59LM818DMBI-37 Toshiba, TC59LM818DMBI-37 Datasheet - Page 10

no-image

TC59LM818DMBI-37

Manufacturer Part Number
TC59LM818DMBI-37
Description
Manufacturer
Toshiba
Type
DDR FCRAMr
Datasheet

Specifications of TC59LM818DMBI-37

Organization
16Mx18
Density
288Mb
Address Bus
17b
Access Time (max)
650ps
Maximum Clock Rate
533MHz
Operating Supply Voltage (typ)
2.5V
Package Type
BGA
Operating Temp Range
-40C to 100C
Operating Supply Voltage (max)
2.625V
Operating Supply Voltage (min)
2.375V
Supply Current
420mA
Pin Count
60
Mounting
Surface Mount
Operating Temperature Classification
Industrial
Lead Free Status / Rohs Status
Not Compliant
AC TEST CONDITIONS
Note:
(1) Transition times are measured between V
(2) If the result of nominal calculation with regard to t
(3) These parameters are measured from the differential clock (CLK and CLK ) AC cross point.
(4) These parameters are measured from signal transition point of DS crossing V
(5) The t
(6) Low Impedance State is specified at V
(7) High Impedance State is specified where output buffer is no longer driven.
(8) These parameters depend on the clock jitter. These parameters are measured at stable clock.
(9) Output timing is measured by using Normal driver strength at V
V
V
V
V
V
Vr
V
SLEW
V
IH (min)
IL (max)
REF
TT
SWING
ID
OTR
Transition (rise and fall) of input signals have a fixed slope.
rounded up to the nearest decimal place.
(i.e., t
The t
In such case, the average interval of eight consecutive Auto-Refresh commands has to be more than 400 ns
always. In other words, the number of Auto-Refresh cycles which can be performed within 3.2 µs (8 × 400 ns)
is to 8 times in the maximum.
SYMBOL
(AC)
V
SWING
REFI (max)
REFI (min)
DSP(min)
SLEW = (V
Input High Voltage (minimum)
Input Low Voltage (maximum)
Input Reference Voltage
Termination Voltage
Input Signal Peak to Peak Swing
Differential Clock Input Reference Level
Input Differential Voltage
Input Signal Minimum Slew Rate
Output Timing Measurement Reference Voltage
= 0.45 × t
applies to both burst refresh method and distributed refresh method.
IH min
applies to equally distributed refresh method.
∆T
(AC) − V
V
V
CK
DDQ
SS
, t
IL max
CK
= 3.75 ns, 0.45 × 3.75 ns = 1.6875 ns is rounded up to 1.7 ns.)
∆T
PARAMETER
(AC))/∆T
DDQ
IH min
/2 ± 0.1 V from steady state.
V
V
V
IH min
REF
IL max
(DC) and V
(AC)
(AC)
CK
contains more than one decimal place, the result is
IL max
DDQ
(DC).
= 1.7 ∼ 1.9V.
V
V
REF
REF
V
V
V
VALUE
V
X
Measurement point
DDQ
DDQ
0.8
1.0
2.5
REF
(AC)
Output
+ 0.2
− 0.2
/2
/2
REF
TC59LM818DMBI-37
level.
AC Test Load
2005-03-07 10/55
25 Ω
UNIT
V/ns
V
V
V
V
V
V
V
V
V
TT
Rev 1.2
NOTES
9

Related parts for TC59LM818DMBI-37