Specifications of EP4CGX150CF23I7N

Number Of Logic Elements/cells
149760
Number Of Labs/clbs
9360
Total Ram Bits
6480000
Number Of I /o
270
Voltage - Supply
1.16 V ~ 1.24 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
484-FBGA
Family Name
Cyclone IV
Number Of Logic Blocks/elements
149760
# I/os (max)
270
Operating Supply Voltage (typ)
1.2V
Logic Cells
149760
Ram Bits
6635520
Operating Supply Voltage (min)
1.16V
Operating Supply Voltage (max)
1.24V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
484
Package Type
FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CGX150CF23I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CGX150CF23I7N
Manufacturer:
ALTERA
0
Part Number:
EP4CGX150CF23I7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CGX150CF23I7N
0
9–8
Accessing Error Detection Block Through User Logic
Cyclone IV Device Handbook, Volume 1
1
The error detection circuit stores the computed 32-bit CRC signature in a 32-bit
register, which is read out by user logic from the core. The cycloneiv_crcblock
primitive is a WYSIWYG component used to establish the interface from the user
logic to the error detection circuit. The cycloneiv_crcblock primitive atom
contains the input and output ports that must be included in the atom. To access the
logic array, the cycloneiv_crcblock WYSIWYG atom must be inserted into your
design.
Figure 9–3
interface that the WYSIWYG atom enables in your design.
Figure 9–3. Error Detection Block Diagram
The user logic is affected by the soft error failure, so reading out the 32-bit CRC
signature through the regout should not be relied upon to detect a soft error. You
should rely on the CRC_ERROR output signal itself, because this CRC_ERROR output
signal cannot be affected by a soft error.
To enable the cycloneiv_crcblock WYSIWYG atom, you must name the atom for
each Cyclone IV device accordingly.
80 MHz Internal Chip Oscillator
shows the error detection block diagram in FPGA devices and shows the
(Saved in the Option Register)
SRAM
Bits
Pre-Computed CRC
Computation
(1 to 256 Factor)
CRC
Clock Divider
Error Detection
Logic