Specifications of EP4CGX150CF23I7N

Number Of Logic Elements/cells
149760
Number Of Labs/clbs
9360
Total Ram Bits
6480000
Number Of I /o
270
Voltage - Supply
1.16 V ~ 1.24 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
484-FBGA
Family Name
Cyclone IV
Number Of Logic Blocks/elements
149760
# I/os (max)
270
Operating Supply Voltage (typ)
1.2V
Logic Cells
149760
Ram Bits
6635520
Operating Supply Voltage (min)
1.16V
Operating Supply Voltage (max)
1.24V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
484
Package Type
FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CGX150CF23I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CGX150CF23I7N
Manufacturer:
ALTERA
0
Part Number:
EP4CGX150CF23I7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CGX150CF23I7N
0
Chapter 1: Cyclone IV Transceivers Architecture
Transceiver Functional Modes
© December 2010 Altera Corporation
1
Clock Rate Compensation
In XAUI mode, the rate match FIFO compensates up to ±100 PPM (200 PPM total)
difference between the upstream transmitter and the local receiver reference clock.
The XAUI protocol requires the transmitter to send /R/ (/K28.0/) code groups
simultaneously on all four lanes (denoted as ||R|| column) during inter-packet
gaps, adhering to rules listed in the IEEE P802.3ae specification.
The rate match operation begins after rx_syncstatus and rx_channelaligned
are asserted. The rx_syncstatus signal is from the word aligner, indicating that
synchronization is acquired on all four channels, while rx_channelaligned signal
is from the deskew FIFO, indicating channel alignment.
The rate match FIFO looks for the ||R|| column (simultaneous /R/ code groups on
all four channels) and deletes or inserts ||R|| columns to prevent the rate match
FIFO from overflowing or under running. The rate match FIFO can insert or delete as
many ||R|| columns as necessary to perform the rate match operation.
The rx_rmfifodatadeleted and rx_rmfifodatainserted flags that indicate
rate match FIFO deletion and insertion events, respectively, are forwarded to the
FPGA fabric. If an ||R|| column is deleted, the rx_rmfifodeleted flag from each
of the four channels goes high for one clock cycle per deleted ||R|| column. If an
||R|| column is inserted, the rx_rmfifoinserted flag from each of the four
channels goes high for one clock cycle per inserted ||R|| column.
The rate match FIFO does not insert or delete code groups automatically to overcome
FIFO empty or full conditions. In this case, the rate match FIFO asserts the
rx_rmfifofull and rx_rmfifoempty flags for at least three recovered clock
cycles to indicate rate match FIFO full and empty conditions, respectively. You must
then assert the rx_digitalreset signal to reset the receiver PCS blocks.