SAB82532H10V32A Infineon Technologies, SAB82532H10V32A Datasheet - Page 58

no-image

SAB82532H10V32A

Manufacturer Part Number
SAB82532H10V32A
Description
IC CONTROLLER 2-CH SER 80-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of SAB82532H10V32A

Controller Type
Serial Communications Controller (SCC)
Interface
Serial
Voltage - Supply
4.75 V ~ 5.25 V
Current - Supply
8mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
80-SQFP
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Other names
SAB82532H10V32A
SAB82532H10V32AIN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAB82532H10V32A
Manufacturer:
Infineon Technologies
Quantity:
10 000
Semiconductor Group
5.2.2
The LAP controllers of the two serial channels can be configured to function in a
half-duplex Normal Response Mode (NRM), where they operate as a slave (secondary)
station, by setting the NRM bit in the XBCH register of the corresponding channel.
In contrast to the full-duplex LAP B/LAP D operation, where the combined
(primary + secondary) station transmits both commands and responses and may
transmit data at any time, the NRM mode allows only responses to be transmitted and
the secondary station may transmit only when instructed to do so by the master (primary)
station. The ESCC2 gets the permission to transmit from the primary station via an S-,
or I-frame with the poll bit (p) set.
The NRM mode can be profitably used in a point-to-multipoint configuration with a fixed
master-slave relationship, which guarantees the absence of collisions on the common
transmit line. It is the responsibility of the master station to poll the slaves periodically
and to handle error situations.
Prerequisite for NRM operation is:
– auto mode with 8-bit address field selected
– external timer mode
– same transmit and receive addresses, since only responses can be transmitted, i.e.
Note: The broadcast address may be programmed in RAL2 if broadcasting is required.
The primary station has to operate in transparent SDLC mode.
MODE: MDS1, MDS0, ADM = ‘000’
MODE: TMD = ‘0’
XAD1 = XAD2 = RAL1 = RAL2 (address of secondary).
In this case RAL1 and RAL2 are not equal.
Half-Duplex SDLC-NRM Operation
58
SAB 82532/SAF 82532
HDLC/SDLC Serial Mode
07.96

Related parts for SAB82532H10V32A