R88A-TK02W Omron, R88A-TK02W Datasheet - Page 229

no-image

R88A-TK02W

Manufacturer Part Number
R88A-TK02W
Description
BKT R88D-WN15H ML2
Manufacturer
Omron
Datasheet

Specifications of R88A-TK02W

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ATK02W
System Design and Installation
3-2-2 Peripheral Device Connection Examples
H
R88D-WTA3HL/-WTA5HL/-WT01HL/-WT02HL/-WTA3H/-WTA5H/-WT01H/-WT02H/-WT04H
User-
controlled
device
Class-3 ground
24 V DC
DC Reactor
Control cable
Noise filter (See note 2.)
Single-phase 100/115 V AC, 50/60 Hz: R88D-WTjjHL
Single-phase 200/230 V AC, 50/60 Hz: R88D-WTjjH
Main-circuit power supply
OMNUC W-series
AC Servo Driver
(See note 1.)
Surge killer (See note 2.)
24 V DC
(See note 3.)
Class-3 ground
Note 1. Set by user parameter Pn50F.
Encoder Cable
Main-circuit connector (See note 2.)
2. Recommended product in 3-2-4 Wiring for Noise
3. Recommended relay: MY Relay (24 V), by
4. The brake is not affected by the polarity of the
Power Cable
Resistance. For conformity to EC Directives,
refer to 3-2-5 Wiring for Conformity to EMC
Directives.
OMRON. For example, an MY2 Relay outputs to
a 2-A inductive load at 24 V DC, making it
applicable to all W-series Motors with Brakes.
power supply.
(See note 4.)
24 V DC
Servo error display
OMNUC W-series
AC Servomotor
Chapter 3
3-15