AD9847AKST Analog Devices Inc, AD9847AKST Datasheet - Page 19

IC CCD SIGNAL PROC 10BIT 48-LQFP

AD9847AKST

Manufacturer Part Number
AD9847AKST
Description
IC CCD SIGNAL PROC 10BIT 48-LQFP
Manufacturer
Analog Devices Inc
Type
CCD Signal Processor, 10-Bitr
Datasheet

Specifications of AD9847AKST

Rohs Status
RoHS non-compliant
Input Type
Logic
Output Type
Logic
Interface
3-Wire Serial
Mounting Type
Surface Mount
Package / Case
48-LQFP
Analog Front End Type
CCD
Analog Front End Category
Video
Interface Type
Serial (3-Wire)
Sample Rate
40MSPS
Input Voltage Range
0.5V
Operating Supply Voltage (min)
2.7/3V
Operating Supply Voltage (typ)
3.3/5V
Operating Supply Voltage (max)
3.6/5.5V
Resolution
10b
Number Of Adc's
1
Power Supply Type
Analog/Digital
Operating Temp Range
-20C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
48
Package Type
LQFP
Number Of Channels
1
Current - Supply
-
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9847AKST
Manufacturer:
AD
Quantity:
1 831
Part Number:
AD9847AKST
Manufacturer:
ADI
Quantity:
244
Part Number:
AD9847AKST
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD9847AKST*
Manufacturer:
a
Quantity:
1
Part Number:
AD9847AKSTZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD9847AKSTZRL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
REV. A
Register Name
SCP1–SCP3
SPTR0–SPTR3
Horizontal Sequence Control
The AD9847 uses sequence change positions (SCP) and sequence
pointers (SPTR) to organize the individual horizontal sequences.
Up to four SCPs are available to divide the readout into four
separate regions, as shown in Figure 12. The SCP 0 is always
hard-coded to line 0, and SCP1–3 are register programmable.
During each region bounded by the SCP, the SPTR registers
designate which sequence is used by each signal. CLPOB, CLPDM,
H1/H3
HBLK
HD
H1/H3
H2/H4
Table VI. Horizontal Sequence Control Parameters for CLPOB, CLPDM, PBLK, and HBLK
Length
12b
2b
SEQUENCE CHANGE OF POSITION #1
SEQUENCE CHANGE OF POSITION #2
SEQUENCE CHANGE OF POSITION #3
SEQUENCE CHANGE OF POSITION #0
UP TO FOUR INDIVIDUAL HORIZONTAL CLAMP AND BLANKING REGIONS MAY BE
PROGRAMMED WITHIN A SINGLE FIELD, USING THE SEQUENCE CHANGE POSITIONS.
0–4095 Line Number
0–3 Sequence Number
Range
Figure 12. Clamp and Blanking Sequence Flexibility
THE POLARITY OF H1 DURING BLANKING IS PROGRAMMABLE (H2 IS OPPOSITE POLARITY OF H1)
. . .
. . .
(V-COUNTER = 0)
Figure 11. HBLK Masking Control
SINGLE FIELD (1 VD INTERVAL)
–19–
CLAMP AND PBLK SEQUENCE REGION 0
CLAMP AND PBLK SEQUENCE REGION 1
CLAMP AND PBLK SEQUENCE REGION 2
CLAMP AND PBLK SEQUENCE REGION 3
PBLK, and HBLK each have a separate set of SCP. For example,
CLPOBSCP1 will define Region 0 for CLPOB, and in that region
any of the four individual CLPOB sequences may be selected
with the CLPOBSPTR registers. The next SCP defines a new
region, and in that region each signal can be assigned to a different
individual sequence. The sequence control registers are summarized
in Table VI.
CLAMP/BLANK SCP to Define Horizontal Regions 0–3
Sequence Pointer for Horizontal Regions 0–3
Description
AD9847
. . .
.
. .

Related parts for AD9847AKST