FLUKE-190-104/AM Fluke Electronics, FLUKE-190-104/AM Datasheet - Page 124

no-image

FLUKE-190-104/AM

Manufacturer Part Number
FLUKE-190-104/AM
Description
SCOPEMETER 4CH 100MHZ COLOR AMER
Manufacturer
Fluke Electronics
Series
ScopeMeter® 190r
Type
Handheldr

Specifications of FLUKE-190-104/AM

Bandwidth
100MHz
Channels
4
Display Type
LCD - Color
Features
DMM, USB Interface, Save, Recall, Record, Trend
Probe Type
10:1 Voltage Probe (1 Blue, 1 Green, 1 Red, 1 Gray)
Sampling Rate (per Second)
1.25GS/s
Input Impedance
1M
Rise Time (typ)
3.5nS
Voltage - Input (max)
CAT III 1000V, CAT IV 600V
Voltage - Supply
7.2V Battery, 17.8VDC Adapter
Includes
Alligator Clips, Battery Charger/Adapter, Case, Hook Clips, Probe Set, Software, Test Leads, USB Cable
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
614-1176
Fluke 190 Series II
Users Manual
Duty Cycle (DUTY)
Range ..................................................... 4.0 % to 98.0 %
Resolution............................. 0.1 % (when period > 2 div)
Full Scale Reading................. 999 counts (3-digit display)
Accuracy (logic or pulse).................... ±(0.5 % +2 counts)
Pulse Width (PULSE)
Resolution (with
Full Scale Reading.......................................... 999 counts
Accuracy
Vpwm
Purpose ................ to measure on pulse width modulated
Principle......... readings show the effective voltage based
Accuracy............................ as Vrms for sinewave signals
V/Hz
Purpose .................... to show the measured Vpwm value
116
1 Hz to full bandwidth...................... ±(0.5 % +2 counts)
(see Vpwm) divided by the fundamental frequency
whole number of periods of the fundamental
GLITCH
signals, like motor drive inverter outputs
on the average value of samples over a
on Variable AC Motor Speed drives.
off) .........................1/100 division
frequency
Accuracy ................................................... %Vrms + %Hz
Power (A and B, C and D)
Power Factor........................ ratio between Watts and VA
Watt ...................................RMS reading of multiplication
VA ................................................................Vrms x Arms
VA Reactive (VAR)........................................
Range......................................................... 0.00 to 1.00
Full Scale Reading .......................................999 counts
Full Scale Reading .......................................999 counts
Full Scale Reading .......................................999 counts
AC motors are designed for use with a rotating
magnetic field of constant strength. This strength
depends on the applied vottage (Vpwm) divided
by the fundamental frequency of the appied
voltage (Hz). The nominal Volt and Hz value are
shown on the motor type plate.
corresponding samples of input A or C (volts)
Note
and Input B or D (amperes)
((VA)
2
-W
2
)