FLUKE-190-104/AM Fluke Electronics, FLUKE-190-104/AM Datasheet - Page 126

no-image

FLUKE-190-104/AM

Manufacturer Part Number
FLUKE-190-104/AM
Description
SCOPEMETER 4CH 100MHZ COLOR AMER
Manufacturer
Fluke Electronics
Series
ScopeMeter® 190r
Type
Handheldr

Specifications of FLUKE-190-104/AM

Bandwidth
100MHz
Channels
4
Display Type
LCD - Color
Features
DMM, USB Interface, Save, Recall, Record, Trend
Probe Type
10:1 Voltage Probe (1 Blue, 1 Green, 1 Red, 1 Gray)
Sampling Rate (per Second)
1.25GS/s
Input Impedance
1M
Rise Time (typ)
3.5nS
Voltage - Input (max)
CAT III 1000V, CAT IV 600V
Voltage - Supply
7.2V Battery, 17.8VDC Adapter
Includes
Alligator Clips, Battery Charger/Adapter, Case, Hook Clips, Probe Set, Software, Test Leads, USB Cable
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
614-1176
Fluke 190 Series II
Users Manual
Meter Measurements for Fluke 190-xx2
The accuracy of all measurements is within ± (% of
reading + number of counts) from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or
above 28 °C.
Meter Input (Banana Jacks)
Input Coupling..............................................................DC
Frequency Response.........................DC to 3 kHz (-3 dB)
Input Impedance ................ 1 MΩ (±1 %)//14 pF (±1.5 pF)
...................................................................1000 V CAT III
....................................................................1000 V CAT II
Meter Functions
Ranging ....................................................... Auto, Manual
Modes.....................................................Normal, Relative
118
Max. Input Voltage Fluke 190-202, -102, -062:
Max. Input Voltage Fluke 190-502:
(For detailed specifications, see “Safety”)
(For detailed specifications, see “Safety”)
600 V CAT IV
600 V CAT III
General
DC Common Mode Rejection (CMRR) ..................>100 dB
AC Common Mode Rejection at 50, 60, or 400 Hz ......>60 dB
Ohms (
Ranges..................................500.0 Ω, 5.000 kΩ, 50.00 kΩ,
Full Scale Reading
Accuracy ............................................... ±(0.6 % +5 counts)
Measurement Current ................... 0.5 mA to 50 nA, ±20 %
Open Circuit Voltage ....................................................<4 V
Continuity (CONT)
Beep ........................................................... <50 Ω (±30 Ω)
Measurement Current ..................................0.5 mA, ±20 %
Detection of shorts of ................................................ ≥1 ms
Diode
Maximum Voltage Reading ......................................2.8 V
Open Circuit Voltage .................................................<4 V
Accuracy ............................................... ±(2 % +5 counts)
Measurement Current ...............................0.5 mA, ±20 %
500 Ω to 5 MΩ...............................................5000 counts
30 MΩ ...........................................................3000 counts
Ω
)
decreases with increasing ranges
500.0 kΩ, 5.000 MΩ, 30.00 MΩ