FLUKE-190-104/AM Fluke Electronics, FLUKE-190-104/AM Datasheet - Page 130

no-image

FLUKE-190-104/AM

Manufacturer Part Number
FLUKE-190-104/AM
Description
SCOPEMETER 4CH 100MHZ COLOR AMER
Manufacturer
Fluke Electronics
Series
ScopeMeter® 190r
Type
Handheldr

Specifications of FLUKE-190-104/AM

Bandwidth
100MHz
Channels
4
Display Type
LCD - Color
Features
DMM, USB Interface, Save, Recall, Record, Trend
Probe Type
10:1 Voltage Probe (1 Blue, 1 Green, 1 Red, 1 Gray)
Sampling Rate (per Second)
1.25GS/s
Input Impedance
1M
Rise Time (typ)
3.5nS
Voltage - Input (max)
CAT III 1000V, CAT IV 600V
Voltage - Supply
7.2V Battery, 17.8VDC Adapter
Includes
Alligator Clips, Battery Charger/Adapter, Case, Hook Clips, Probe Set, Software, Test Leads, USB Cable
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
614-1176
Fluke 190 Series II
Users Manual
Miscellaneous
Display
View Area .............. 126.8 x 88.4 mm (4.99 x 3.48 inches)
Resolution............................................... 320 x 240 pixels
Backlight ...................... LED (Temperature compensated)
Brightness............................... Power Adapter: 200 cd/m
Display Auto-OFF time (battery saving) .........30 seconds,
FLUKE 190-xx4: Rechargeable Li-ion Battery (model
BP291):
FLUKE 190-xx2: Rechargeable Li-ion Battery (model
BP290):
122
Operating Time ................. up to 7 hours (Low Intensity)
Charging Time ................................................... 5 hours
Capacity/Voltage.................................... 52 Wh / 10.8 V
Operating Time ................. up to 4 hours (Low Intensity)
Charging Time ................................................ 2.5 hours
Capacity/Voltage.................................... 26 Wh / 10.8 V
Power
Battery Power: 90 cd/ m
5 minutes or disabled
2
2
Rechargeable Li-ion Battery (model BP 290 and BP291):
Power Adapter BC190:
• BC190/801 European line plug 230 V ±10 %
• BC190/813 North American line plug 120 V ±10 %
• BC190/804 United Kingdom line plug 230 V ±10 %
• BC190/806 Japanese line plug 100 V ±10 %
• BC190/807 Australian line plug 230 V ±10 %
• BC190/808 Universal switchable adapter 115 V ±10 %
Line Frequency .......................................... 50 and 60 Hz
Probe Calibration
Manual pulse adjustment and automatic DC adjustment
with probe check
Generator Output ............................... 1.225 Vpp / 500 Hz
Life Time (> 80 % capacity)........300x charge/discharge
Allowable ambient
temperature during charging: .....0 to 40 °C (32 to 104 °F)
Auto power down
time (battery saving):..............5 min, 30 min or disabled
or 230 V ±10 %, with plug EN60320-2.2G
square wave