RFW-D100 Vishay, RFW-D100 Datasheet - Page 20

no-image

RFW-D100

Manufacturer Part Number
RFW-D100
Description
Manufacturer
Vishay
Datasheet

Specifications of RFW-D100

Operating Temperature (min)
0C
Operating Temperature (max)
70C
Operating Temperature Classification
Commercial
Package Type
LQFP
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RFW-D100-LF
Manufacturer:
CTC
Quantity:
3 186
RFW-D100
Vishay RFWaves
Bit 2: RX_FIFO_RESET
This bit resets the RX_FIFO address pointers when set
to logic 1. This bit is set by the MCU and is cleared
automatically by the RFW-D100.
Bit 3: TX_FIFO_RESET
This bit resets the TX_FIFO address pointers when set
to logic 1. This bit is set by the MCU and is cleared
automatically by the RFW-D100.
Bit 4: STOP_RX
This bit stops receiving the current packet, resets the
RX_FIFO counters, and start new searches for
PREAMBLE. This bit is set by the MCU and is cleared
automatically by the RFW-D100.
Bits 5-7: PRE_MASK [0:2]
These bits determine the mask on PRE-H in
PREAMBLE correlation. Meaning, it determines the
SYSTEM CONTROL REGISTER 3 (SCR3)
This register is a read/write register.
Bit 1: EN_CAP_DISCH
Enables/disables the capacitor discharge mechanism
that discharges the reference capacitor after each
received packet:
1: Enables discharge.
0: Disables discharge.
This bit overrides bit 3.
Bit 2: CAP_DIS_PERIOD
Determines the capacitor discharge duration:
1: The pulse width is 72 clocks (3 µsec at 24 MHz
clock).
0: The pulse width is 36 clocks (3 µsec at 12 MHz
clock).
The recommended discharge period should be at least
3 µsec.
If the RFW-D100 oscillator frequency is bigger than
12 MHz
Bit 3: EN_ZERO_DISCH
Enables/disables zero counter capacitor discharge
mechanism:
1: Enables zero counter capacitor discharge.
0: Disables zero counter capacitor discharge.
www.vishay.com
20
Name
SCR3
Not Used
Bit 7
ZERO DISCH
CNT 2
Bit 6
For more information please contact: RFTransceivers@vishay.com
ZERO DISCH
CNT 0
BIt 5
ZERO DISCH
CNT 0
Bit 4
size of the PREAMBLE in the receiver.
The PRE-L is always used in the PREAMBLE correla-
tion.
The RFW-D100 cuts off bit from PRE-H register,
starting from the MSB.
Default Value: 0 x 40
Bits 4-6: ZERO_DISCH_CNT [0:2]
Determines the number of consecutive zero bits that
will trigger a capacitor discharge by the zero counter
capacitor discharge mechanism.
Bit 7: Not in Use
This bit must be 0 at all times for the RFW-D100 to
work properly.
Default Value: 0 x 01
PRE_MASK 2 PRE_MASK 1 PRE_MASK 0
ZERO DISCH
CNT 2
EN ZERO
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
DISCH
Bit 3
ZERO DISCH
CNT 1
CAP DIS
PERIOD
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
Bit 2
ZERO DISCH
CNT 0
EN CAP
DISCH
Bit 1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Document Number 84675
Rev. 1.1, 22-Jan-07
PREAMBLE
Number of
Zeros
size
Bit 0
20
30
40
50
60
70
80
90
16
15
14
13
12
11
10
9