STEVAL-IPE012V1 STMicroelectronics, STEVAL-IPE012V1 Datasheet - Page 30

no-image

STEVAL-IPE012V1

Manufacturer Part Number
STEVAL-IPE012V1
Description
EVAL BOARD ENERGY METER
Manufacturer
STMicroelectronics
Series
-r

Specifications of STEVAL-IPE012V1

Design Resources
STEVAL-IPE012V1 Schematic STEVAL-IPE012V1 BOM
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
STPM10BTR, STM8L152
Primary Attributes
Single Phase with 1 Current Transformer & Shunt
Secondary Attributes
Tamper Detection
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-11462
Theory of operation
Table 11.
1. IMPORTANT: This bit represents the MSB of the decimal value indicated in the description column.
7.18
Table 12.
30/51
110000
110001 49
110010
110011
110100
110101
110110
110111
Bit #
binary
6-bit
0
1
2
3
Address
Reserved
Reserved
Reserved
Signal
BANK
name
DEC
48
50
51
52
53
54
55
(1)
Configuration bit map (continued)
As indicated above, the STPM10 includes 56 CFG bits. The CFG bits are not retained when
the STPM10 supply is not available and they are cleared when a POR occurs, but they are
not cleared when a remote reset command (RRR) is sent through SPI.
Normally, some of these bits must be loaded during power-up of the application. From the
microcontroller, it could also reload the configuration and calibration values after power-on
restart.
Mode signals
The STPM10 includes 8 mode signals located in the DFP data record. 3 of these are used
only for internal testing purposes while 5 are useful to change some of the operations of the
STPM10. The mode signals are not retained when the STPM10 supply is not available and
they are cleared when a POR occurs, but they are not cleared when a remote reset
command (RRR) is sent through SPI.
The mode signals bit can be written using the normal writing procedure of the SPI interface
(see
Mode signal description
Name
CRIT
CRC
Section 7.19
-
-
-
-
-
value
Bit
0
1
n. of
bits
2
1
1
1
1
1
1
Used for RC startup procedure
).
2-bit unsigned data for calibration of RC oscillator. (see
CRC=0, or CRC=3 cal=0%
CRC=1, cal=+10%;
CRC=2, cal=-10%.
Reserved
Reserved
Reserved
Selection of tamper threshold:
CRIT=0: 12,5% / CRIT=1: 6,25%
Reserved
Reserved (always set to 1 after production testing of die)
Doc ID 17728 Rev 3
Status
Description
(1)
command
0111000x
1111000x
Binary
Table
5)
command
F0 or F1
70 or 71
Hex
STPM10

Related parts for STEVAL-IPE012V1