DS21Q50L Maxim Integrated Products, DS21Q50L Datasheet - Page 29

IC TRANSCEIVER E1 QUAD 100-LQFP

DS21Q50L

Manufacturer Part Number
DS21Q50L
Description
IC TRANSCEIVER E1 QUAD 100-LQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS21Q50L

Function
Transceiver
Interface
E1
Number Of Circuits
4
Voltage - Supply
3.14 V ~ 3.47 V
Current - Supply
230mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LQFP
Includes
AIS Alarms Detector and Generator, Loopback Functions, PRBS Generator / Detector, Remote Detector and Generator
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS21Q50L
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q50L
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS21Q50L+
Quantity:
5 530
Part Number:
DS21Q50L+
Manufacturer:
SPANSION
Quantity:
119
Part Number:
DS21Q50L+
Manufacturer:
MAXIM
Quantity:
3
Part Number:
DS21Q50L+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q50L+
Manufacturer:
ST
0
Part Number:
DS21Q50L-W+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q50LN
Manufacturer:
NS
Quantity:
12
Part Number:
DS21Q50LN
Manufacturer:
Maxim Integrated
Quantity:
10 000
4.3 Automatic Alarm Generation
The device can be programmed to automatically transmit AIS or remote alarm. When automatic AIS
generation is enabled (CCR2.5 = 1), the device monitors the receive framer to determine if any of the
following conditions are present: loss of receive frame synchronization, AIS alarm (all ones) reception, or
loss-of-receive carrier (or signal). If any one (or more) of the above conditions is present, then the framer
forces an AIS alarm.
When automatic RAI generation is enabled (CCR2.4 = 1), the framer monitors the receive to determine if
any of the following conditions are present: loss-of-receive frame synchronization, AIS alarm (all ones)
reception, or loss-of-receive carrier (or signal), or if CRC4 multiframe synchronization cannot be found
within 128ms of FAS synchronization (if CRC4 is enabled). If any one (or more) of the above conditions
is present, the framer transmits an RAI alarm. RAI generation conforms to ETS 300 011 specifications
and a constant remote alarm is transmitted if the DS21Q50 cannot find CRC4 multiframe synchronization
within 400ms as per G.706.
Register Name:
Register Description:
Register Address:
Bit
Name
NAME
TCM4
TCM3
TCM2
TCM1
TCM0
LIAIS
RLB
LLB
RLB
7
BIT
7
6
5
4
3
2
1
0
LLB
Remote Loopback. See Section
0 = loopback disabled
1 = loopback enabled
Local Loopback. See Section
0 = loopback disabled
1 = loopback enabled
Line Interface AIS Generation Enable
0 = allow normal data to be transmitted at TTIP and TRING
1 = force unframed all ones to be transmitted at TTIP and TRING at the MCLK rate
Transmit Channel Monitor Bit 4. MSB of a channel decode that determines which transmit
channel data appear in the TDS0M register. See Section
Transmit Channel Monitor Bit 3
Transmit Channel Monitor Bit 2
Transmit Channel Monitor Bit 1
Transmit Channel Monitor Bit 0. LSB of the channel decode.
6
CCR3
Common Control Register
14 Hex
LIAIS
5
TCM4
4
4.5
29 of 87
4.4
TCM3
for details.
3
for details.
FUNCTION
TCM2
2
TCM1
6
1
or details.
TCM0
0

Related parts for DS21Q50L