AT32UC3B1128 Atmel Corporation, AT32UC3B1128 Datasheet - Page 588

no-image

AT32UC3B1128

Manufacturer Part Number
AT32UC3B1128
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3B1128

Flash (kbytes)
128 Kbytes
Pin Count
48
Max. Operating Frequency
60 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
28
Ext Interrupts
28
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
1
Uart
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
6
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0-3.6 or (1.65-1.95+3.0-3.6)
Operating Voltage (vcc)
3.0-3.6 or (1.65-1.95+3.0-3.6)
Fpu
No
Mpu / Mmu
Yes / No
Timers
10
Output Compare Channels
16
Input Capture Channels
6
Pwm Channels
13
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3B1128-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3B1128-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3B1128-U
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
27.4.11.1
27.4.11.2
27.4.11.3
27.4.11.4
32059L–AVR32–01/2012
Canceling a SAB Access
Busy Reporting
SAB Address Mode
Block Transfer
For more information about the SAB and a list of SAB slaves see the Service Access Bus
chapter.
The MEMORY_SIZED_ACCESS instruction allows a sized read or write to any 36-bit address
on the bus. MEMORY_WORD_ACCESS is a shorthand instruction for 32-bit accesses to any
36-bit address, while the NEXUS_ACCESS instruction is a Nexus-compliant shorthand instruc-
tion for accessing the 32-bit OCD registers in the 7-bit address space reserved for these. These
instructions require two passes through the Shift-DR TAP state: one for the address and control
information, and one for data.
To increase the transfer rate, consecutive memory accesses can be accomplished by the
MEMORY_BLOCK_ACCESS instruction, which only requires a single pass through Shift-DR for
data transfer only. The address is automatically incremented according to the size of the last
SAB transfer.
It is possible to abort an ongoing SAB access by the CANCEL_ACCESS instruction, to avoid
hanging the bus due to an extremely slow slave.
As the time taken to perform an access may vary depending on system activity and current chip
frequency, all the SAB access JTAG instructions can return a busy indicator. This indicates
whether a delay needs to be inserted, or an operation needs to be repeated in order to be suc-
cessful. If a new access is requested while the SAB is busy, the request is ignored.
The SAB becomes busy when:
The SAB becomes ready again when:
What to do if the busy bit is set:
• Entering Update-DR in the address phase of any read operation, e.g., after scanning in a
• Entering Update-DR in the data phase of any write operation, e.g., after scanning in data for
• Entering Update-DR during a MEMORY_BLOCK_ACCESS.
• Entering Update-DR after scanning in a counter value for SYNC.
• Entering Update-IR after scanning in a MEMORY_BLOCK_ACCESS if the previous access
• A read or write operation completes.
• A SYNC countdown completed.
• A operation is cancelled by the CANCEL_ACCESS instruction.
• During Shift-IR: The new instruction is selected, but the previous operation has not yet
• During Shift-DR of an address: The new address is ignored. The SAB stays in address mode,
NEXUS_ACCESS address with the read bit set.
a NEXUS_ACCESS write.
was a read and data was scanned after scanning the address.
completed and will continue (unless the new instruction is CANCEL_ACCESS). You may
continue shifting the same instruction until the busy bit clears, or start shifting data. If shifting
data, you must be prepared that the data shift may also report busy.
so no data must be shifted. Repeat the address until the busy bit clears.
588

Related parts for AT32UC3B1128