ST72324J6 STMicroelectronics, ST72324J6 Datasheet - Page 19

no-image

ST72324J6

Manufacturer Part Number
ST72324J6
Description
8-BIT MCU WITH NESTED INTERRUPTS, FLASH, 10-BIT ADC, 4 TIMERS, SPI, SCI INTERFACE
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST72324J6

Hdflash Endurance
100 cycles, data retention
Clock Sources
crystal/ceramic resonator oscillators, internal RC oscillator, clock security system and bypass for external clock
Four Power Saving Modes
Halt, Active-Halt, Wait and Slow
Main Clock Controller With
Real time base, Beep and Clock-out capabilities
16-bit Timer A With
1 input capture, 1 output compare, external clock input, PWM and pulse generator modes
16-bit Timer B With
2 input captures, 2 output compares, PWM and pulse generator modes
FLASH PROGRAM MEMORY (Cont’d)
4.5 ICP (In-Circuit Programming)
To perform ICP the microcontroller must be
switched to ICC (In-Circuit Communication) mode
by an external controller or programming tool.
Depending on the ICP code downloaded in RAM,
Flash memory programming can be fully custom-
ized (number of bytes to program, program loca-
tions, or selection serial communication interface
for downloading).
When using an STMicroelectronics or third-party
programming tool that supports ICP and the spe-
cific microcontroller device, the user needs only to
implement the ICP hardware interface on the ap-
plication board (see
the pin locations, refer to the device pinout de-
scription.
4.6 IAP (In-Application Programming)
This mode uses a BootLoader program previously
stored in Sector 0 by the user (in ICP mode or by
plugging the device in a programming tool).
This mode is fully controlled by user software. This
allows it to be adapted to the user application, (us-
er-defined strategy for entering programming
mode, choice of communications protocol used to
fetch the data to be stored, etc.). For example, it is
Table 4. Flash Control/Status Register Address and Reset Value
Address
(Hex.)
0029h
FCSR
Reset Value
Register
Label
Figure
7). For more details on
7
0
6
0
5
0
possible to download code from the SPI, SCI, USB
or CAN interface and program it in the Flash. IAP
mode can be used to program any of the Flash
sectors except Sector 0, which is write/erase pro-
tected to allow recovery in case errors occur dur-
ing the programming operation.
4.7 Related Documentation
For details on Flash programming and ICC proto-
col, refer to the ST7 Flash Programming Refer-
ence Manual and to the ST7 ICC Protocol Refer-
ence Manual
4.7.1 Register Description
FLASH CONTROL/STATUS REGISTER (FCSR)
Read/Write
Reset Value: 0000 0000 (00h)
This register is reserved for use by Programming
Tool software. It controls the Flash programming
and erasing operations.
7
0
4
0
0
.
3
0
0
0
ST72324Jx ST72324Kx
2
0
0
0
1
0
0
19/164
0
0
0
0
1

Related parts for ST72324J6