MT9074 Mitel Networks Corporation, MT9074 Datasheet - Page 96

no-image

MT9074

Manufacturer Part Number
MT9074
Description
T1/E1/J1 Single Chip Transceiver
Manufacturer
Mitel Networks Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9074AL
Manufacturer:
ZARLINK
Quantity:
1 238
Part Number:
MT9074AL1
Manufacturer:
ZARLINK
Quantity:
22
Part Number:
MT9074AP
Manufacturer:
MITEL
Quantity:
14
Part Number:
MT9074AP
Manufacturer:
ZARLINK
Quantity:
20 000
Part Number:
MT9074AP1
Manufacturer:
ZARLINK
Quantity:
227
Part Number:
MT9074APR1
Manufacturer:
ZARLINK
Quantity:
227
MT9074
96
Bit
7
6
5
4
3
2
1
0
TXMSG
RPSIG
Name
RTST
RTSL
TTST
LTSL
ADI
- - -
Table 135 - Per Time Slot Control Words (Pages 7 and 8) (E1)
Transmit Message Mode. if high, the data from the corresponding address
location of Tx message mode buffer is transmitted in the corresponding PCM 30
time slot. If zero, the data on DSTI is transmitted on the corresponding PCM 30
time slot.
Alternate Digit Inversion. If one, the corresponding transmit time slot data on
DSTI has every second bit inverted. If zero, this bit has no effect on channel data.
Remote Time Slot Loopback. If one, the corresponding PCM 30 receive time slot
is looped to the corresponding PCM 30 transmit time slot. This received time slot
will also be present on DSTO. If zero, the loopback is disabled.
Local Time Slot Loopback. If one, the corresponding transmit time slot is looped
to the corresponding receive time slot. This transmit time slot will also be present on
the transmit PCM 30 stream. If zero, this loopback is disabled.
Transmit Test. If one, a test signal, either digital milliwatt (when control bit ADSEQ
is one) or PRBS (2
PCM 30 time slot. More than one time slot may be activated at once. If zero, the
test signal will not be connected to the corresponding time slot.
Receive Test. If one, the corresponding DSTo time slot will be used for testing. If
control bit ADSEQ is one, a digital milliwatt signal will be transmitted into the DSTo
channel. If ADSEQ is zero, the receive channel will be connected to the PRBS (2
- 1) detector
Serial Signaling Enable. If one, the transmit CAS signalling will be controlled by
programming Page 05H. If zero, the transmit CAS signalling will be controlled
through the CSTI stream.
Unused.
15
-1) (ADSEQ is zero), will be transmitted in the corresponding
Functional Description
Advance Information
15