si3200-x-gs Silicon Laboratories, si3200-x-gs Datasheet - Page 102

no-image

si3200-x-gs

Manufacturer Part Number
si3200-x-gs
Description
Dual Programmable Cmos Slic With Line Monitoring
Manufacturer
Silicon Laboratories
Datasheet
Si3232
LONGLOTH: Ground Key Removal Detection Threshold (RAM Address 28)
Reset settings = 0x00
LONGLPF: Ground Key Filter Coefficient (RAM Address 30)
Reset settings = 0x00
PLPF12: Q1/Q2 Thermal Low-pass Filter Coefficient (RAM Address 40)
Reset settings = 0x00
102
15:0
15:3
15:3
Name
Name
Name
Type
Type
Type
Bit
Bit
Bit
Bit
Bit
Bit
LONGLOTH[15:0]
LONGLPF[15:3]
D15
D15
D15
PLPF12[15:3]
Name
Name
Name
D14
D14
D14
D13
D13
D13
Ground Key Removal Detection Threshold.
Programs the longitudinal current threshold at which it is determined that a ground
key event has been terminated. 0 to 101.09 mA programmable range, 3.097 µ A/
LSB, 396.4 µ A effective resolution. Usable range is 0 to 16 mA.
Ground Key Filter Coefficient.
Programs the digital low-pass filter block in the ground key detection circuit. Refer to
"4.5.2. Ground Key Detection" on page 34 for calculation.
Q1/Q2 Thermal Low-pass Filter Coefficient.
Programs the thermal low-pass filter value used to calculate the power in transistors
Q1 and Q2. Also used to set thermal IPF when using Si3200. Refer to "4.4.6. Power
Filter and Alarms" on page 27 for use.
D12
D12
D12
D11
D11
D11
D10
D10
D10
LONGLPF[15:3]
PLPF12[15:3]
Preliminary Rev. 0.96
R/W
R/W
D9
D9
D9
LONGLOTH[15:0]
D8
D8
D8
R/W
D7
D7
D7
Function
Function
Function
D6
D6
D6
D5
D5
D5
D4
D4
D4
D3
D3
D3
D2
D2
D2
D1
D1
D1
D0
D0
D0

Related parts for si3200-x-gs