LINEFEED: Linefeed Control (Register Address 6)
(Register type: Operational)
Reset settings = 0x00
76
Name
Type
Bit
6:4
2:0
Bit
7
3
Reserved
Reserved
LFS[2:0]
LF[2:0]
Name
D7
D6
Read returns zero.
Linefeed Shadow.
This register reflects the actual realtime linefeed status. Automatic operations may cause
actual linefeed state transitions regardless of the Linefeed register settings (e.g., when
the Linefeed register is in the ringing state, the Linefeed Shadow register will reflect the
ringing state during ringing bursts and the OHT state during silent periods between ring-
ing bursts).
000 = Open
001 = Forward Active
010 = Forward On-hook Transmission (OHT)
011 = TIP Open
100 = Ringing
101 = Reverse Active
110 = Reverse On-hook Transmission
111 = RING Open
Read returns zero.
Linefeed.
Writing to this register sets the linefeed state.
000 = Open
001 = Forward Active
010 = Forward On-hook Transmission (OHT)
011 = TIP Open
100 = Ringing
101 = Reverse Active
110 = Reverse On-hook Transmission
111 = RING Open